Certified by EPA ENERGY STAR, Air King AK80LS delivers 80 CFM free-air (61.5 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 4.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 61 sq ft (8-ft height) or 54 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK80LS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 61.5 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 76.9% @ 0.25"
- Motor Draw
- 17.8 W (6.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Air King AK80LS vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.5 CFM at 0.25 in. w.g. (76.9% retention, 10.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2312825 verifies AK80LS (series: Air King) under Air King (62 listed models, qualified 2018-03-16). Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.8 watts, about 6.5 kWh/yr (~$1.04/yr at $0.16/kWh) for 1 hr/day shower timers or 155.9 kWh/yr (~$24.94/yr) continuously. Closest competing matches include ACIQ AES80 (80.0 CFM) and CFM TF80N (80.0 CFM).
How noisy is Air King AK80LS compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Air King AK80LS measures 0.7 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Air King AK80LS airflow?
Connecting Air King AK80LS through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Air King AK80LS performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King AK80LS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK80LS / Air King | PD ID 2312825 (Qualified 2018-03-16) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (61.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Air King AK80LS?
Calculated coverage metrics translate Air King AK80LS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 61 sq ft | 1 CFM/sq ft @ 61.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 54 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.5 kWh/yr (~$1.04/yr) | 17.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 155.9 kWh/yr (~$24.94/yr) | 17.8 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Air King AK80LS?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AES80 | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| CFM TF80N | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Ortech ODE-8007 | 80 / 69.8 CFM | 0.7 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| S&P PCLP80XP | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| ACIQ AEP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
Does Air King AK80LS match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King AK80LS percentage capacity without sending data.
Which bath layouts should avoid specifying Air King AK80LS?
Match Air King AK80LS directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 61.5 CFM net static output
- Optimal use: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Air King AK80LS?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King AK80LS.
What bathroom square footage can Air King AK80LS ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Air King AK80LS covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Air King AK80LS run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Air King AK80LS.
What happens to Air King AK80LS CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Air King AK80LS moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Air King AK80LS sit on acoustic comfort for senior homeowners?
Measuring 0.7 sones, Air King AK80LS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Air King AK80LS cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Air King AK80LS 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Air King AK80LS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK80LS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King AK80LS?
Air King AK80LS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King AK80LS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK80LS's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)