Rated for 80 CFM open-air (64.4 CFM at 0.25 in. w.g.), Delta GBR80LED registers #194 of 607 in quietness (0.8 sones) and delivers 7.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 64 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta GBR80LED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 64.4 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 7.3 CFM/W (#400/1,145)
- Static Retention
- 80.5% @ 0.25"
- Motor Draw
- 11.0 W (4.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta GBR80LED vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 64.4 CFM at 0.25 in. w.g. (80.5% retention, 7.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Delta registers 121 certified models, with SKU GBR80LED (series: BreezGreenBuilder) (PD #2389096) certified since 2021-10-15. Lighting kit: Yes. At 7.3 CFM/W (#400 of 1,145, top 35.5% of 1,145 rated models, more efficient than 64.5% of rated models, 2.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.0 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 96.4 kWh/yr (~$15.42/yr) continuously. Closest competing matches include Anzzi EF-AZ101WH (80.0 CFM) and Aria QBV0800 (80.0 CFM).
How does Delta GBR80LED acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Delta GBR80LED (0.8 sones).
How do flex elbows choke Delta GBR80LED at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Delta GBR80LED moving full rated CFM.
Does Delta GBR80LED meet residential exhaust fan code specs?
Inspect Delta GBR80LED mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | GBR80LED / BreezGreenBuilder | PD ID 2389096 (Qualified 2021-10-15) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (64.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Delta GBR80LED airflow output?
Annual electricity figures and room square-footage ceilings below reflect Delta GBR80LED tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 64 sq ft | 1 CFM/sq ft @ 64.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 57 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.0 kWh/yr (~$0.64/yr) | 11.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 96.4 kWh/yr (~$15.42/yr) | 11.0 W x 8,760 hrs / 1,000 |
Which competing models share Delta GBR80LED airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Anzzi EF-AZ101WH | 80 / 68.9 CFM | 0.7 sones (-0.10) | 5.3 CFM/W | 4 in. diameter |
| Aria QBV0800 | 80 / 68.9 CFM | 0.7 sones (-0.10) | 5.3 CFM/W | 4 in. diameter |
| Haier QVE801DTWW | 80 / 68.9 CFM | 0.7 sones (-0.10) | 5.3 CFM/W | 4 in. diameter |
| Delta 80HLED | 80 / 64.4 CFM | 0.8 sones (Same) | 7.3 CFM/W | 4 in. diameter |
| Delta 80LED-ADJ | 80 / 64.4 CFM | 0.8 sones (Same) | 7.3 CFM/W | 4 in. diameter |
How much airflow margin does Delta GBR80LED give your bath?
Run a quick local room-volume check for Delta GBR80LED by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Delta GBR80LED?
Match Delta GBR80LED directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 64 sq ft with 8-ft ceilings (57 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Delta GBR80LED?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta GBR80LED.
Where does Delta GBR80LED run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta GBR80LED.
What happens to Delta GBR80LED CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Delta GBR80LED moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Delta GBR80LED sit on acoustic comfort for senior homeowners?
Measuring 0.8 sones, Delta GBR80LED operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Delta GBR80LED cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Delta GBR80LED 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Delta GBR80LED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta GBR80LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta GBR80LED?
Delta GBR80LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta GBR80LED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta GBR80LED's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Delta GBR80LED ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta GBR80LED covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)