Delta 80LED-ADJ Exhaust Fan Specifications

ENERGY STAR PD #2389095 · Bathroom/Utility Room · Qualified 2021-10-15
Verified Specification Summary

Tested under HVI protocols, the Delta 80LED-ADJ exhaust unit achieves 80 CFM at 0.1 in. w.g. (64.4 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones) and delivers 7.3 CFM/W efficacy, covering standard baths up to 64 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 80LED-ADJ Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 64.4 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
7.3 CFM/W (#400/1,145)
Static Retention
80.5% @ 0.25"
Motor Draw
11.0 W (4.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta 80LED-ADJ vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 64.4 CFM at 0.25 in. w.g. (80.5% retention, 7.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Delta maintains 121 active ENERGY STAR blowers; 80LED-ADJ (series: BreezGreenBuilder) (PD #2389095) gained qualification on 2021-10-15. Lighting kit: Yes. At 7.3 CFM/W (#400 of 1,145, top 35.5% of 1,145 rated models, more efficient than 64.5% of rated models, 2.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.0 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 96.4 kWh/yr (~$15.42/yr) continuously. Closest competing matches include Anzzi EF-AZ101WH (80.0 CFM) and Aria QBV0800 (80.0 CFM).

Where do Delta 80LED-ADJ sones rank across EPA ENERGY STAR fans?

Comparing Delta 80LED-ADJ (0.8 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

What attic duct routing preserves Delta 80LED-ADJ CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta 80LED-ADJ, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Delta 80LED-ADJ measure up on airflow and noise ratings?

Each row below breaks down Delta 80LED-ADJ certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series 80LED-ADJ / BreezGreenBuilder PD ID 2389095 (Qualified 2021-10-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (64.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Delta 80LED-ADJ CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta 80LED-ADJ
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 64 sq ft1 CFM/sq ft @ 64.4 CFM
Tall Bath (9-ft Ceiling)Up to 57 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.0 kWh/yr (~$0.64/yr)11.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.296.4 kWh/yr (~$15.42/yr)11.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Delta 80LED-ADJ?

Compare Delta 80LED-ADJ side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Anzzi EF-AZ101WH 80 / 68.9 CFM 0.7 sones (-0.10) 5.3 CFM/W 4 in. diameter
Aria QBV0800 80 / 68.9 CFM 0.7 sones (-0.10) 5.3 CFM/W 4 in. diameter
Haier QVE801DTWW 80 / 68.9 CFM 0.7 sones (-0.10) 5.3 CFM/W 4 in. diameter
Delta 80HLED 80 / 64.4 CFM 0.8 sones (Same) 7.3 CFM/W 4 in. diameter
Delta GBR80LED 80 / 64.4 CFM 0.8 sones (Same) 7.3 CFM/W 4 in. diameter

Can you size Delta 80LED-ADJ for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta 80LED-ADJ verified capacity.

Who should not install Delta 80LED-ADJ in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta 80LED-ADJ for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 64.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 0.8 sones up to 64 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Delta 80LED-ADJ?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta 80LED-ADJ.

Does Delta 80LED-ADJ satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta 80LED-ADJ clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Delta 80LED-ADJ undersized or poorly matched for a bath renovation?

Skip Delta 80LED-ADJ if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Delta 80LED-ADJ CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta 80LED-ADJ registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Delta 80LED-ADJ sound output compare to noisy contractor-grade fans?

Rated at 0.8 sones, Delta 80LED-ADJ operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Delta 80LED-ADJ?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Delta 80LED-ADJ pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 80LED-ADJ's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta 80LED-ADJ?

Delta 80LED-ADJ features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta 80LED-ADJ's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 80LED-ADJ's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)