Certified by EPA ENERGY STAR, Delta GBR80 delivers 80 CFM free-air (68.8 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 9.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 68 sq ft (8-ft height) or 61 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta GBR80 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 68.8 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 9.5 CFM/W (#234/1,145)
- Static Retention
- 86.0% @ 0.25"
- Motor Draw
- 8.4 W (3.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta GBR80 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.8 CFM out of 80 CFM (86.0% retention, 1.7 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Delta maintains 121 active ENERGY STAR blowers; GBR80 (series: Delta/BreezGreenBuilder) (PD #2267015) gained qualification on 2016-05-16. Lighting kit: No. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.4 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 73.6 kWh/yr (~$11.78/yr) continuously. Closest competing matches include Delta 80F (80.0 CFM) and Delta 80F-DGL (80.0 CFM).
How noisy is Delta GBR80 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Delta GBR80 measures 0.8 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Delta GBR80 airflow?
Connecting Delta GBR80 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Delta GBR80 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta GBR80 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | GBR80 / Delta/BreezGreenBuilder | PD ID 2267015 (Qualified 2016-05-16) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (68.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Delta GBR80?
Calculated coverage metrics translate Delta GBR80 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 61 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.1 kWh/yr (~$0.50/yr) | 8.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 73.6 kWh/yr (~$11.78/yr) | 8.4 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Delta GBR80?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta 80F | 80 / 68.8 CFM | 0.8 sones (Same) | 9.5 CFM/W | 4 in. diameter |
| Delta 80F-DGL | 80 / 68.8 CFM | 0.8 sones (Same) | 9.5 CFM/W | 4 in. diameter |
| Panasonic RG-S80LHA | 80 / 83.9 CFM | 0.5 sones (-0.30) | 9.3 CFM/W | 4 in. diameter |
| Revent RVL80 | 80 / 89 CFM | 0.8 sones (Same) | 12.0 CFM/W | 4 in. diameter |
| KORA SBF90DC-MS | 98.1 / N/A CFM | 0.7 sones (-0.10) | 10.7 CFM/W | 4 in. diameter |
Does Delta GBR80 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta GBR80 percentage capacity without sending data.
When does Delta GBR80 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta GBR80.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 68.8 CFM net static output
- Target scenario: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Delta GBR80?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta GBR80.
Is Delta GBR80 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta GBR80 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Delta GBR80?
Do not force Delta GBR80 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Delta GBR80 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Delta GBR80 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Delta GBR80 disturb adjacent bedrooms during night use?
Acoustic measurement places Delta GBR80 at 0.8 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Delta GBR80 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Delta GBR80 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Delta GBR80 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta GBR80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta GBR80?
Delta GBR80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta GBR80's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta GBR80's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)