Skip to main content
Grant Estimator

Revent RVL80 Exhaust Fan Specifications

ENERGY STAR PD #4619019 · Bathroom/Utility Room · Qualified 2026-05-06
Verified Specification Summary

Homeowners specifying Revent RVL80 gain 80 CFM at 0.1 in. w.g. (89 CFM at 0.25 in. w.g.) where it registers #194 of 607 in quietness (0.8 sones) and delivers 12.0 CFM/W efficacy, venting bathrooms up to 89 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVL80 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 89 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
12.0 CFM/W (#80/1,145)
Static Retention
111.2% @ 0.25"
Motor Draw
6.7 W (2.4 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVL80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 89 CFM out of 80 CFM (111.2% retention, 23.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Revent registers 40 certified models, with SKU RVL80 (series: ReVent) (PD #4619019) certified since 2026-05-06. Lighting kit: Yes. At 12.0 CFM/W (#80 of 1,145, top 7.3% of 1,145 rated models, more efficient than 92.7% of rated models, 7.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.7 watts, about 2.4 kWh/yr (~$0.38/yr at $0.16/kWh) for 1 hr/day shower timers or 58.7 kWh/yr (~$9.39/yr) continuously. Closest competing matches include Ortech ODD-90-1 (95.0 CFM) and Delta 80F (80.0 CFM).

What acoustic percentile does Revent RVL80 occupy among 1,145 bath blowers?

Inspect how Revent RVL80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Which exterior damper path suits Revent RVL80 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Revent RVL80 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Revent RVL80 acoustic and static metrics stand?

Compare Revent RVL80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVL80 / ReVent PD ID 4619019 (Qualified 2026-05-06)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (89 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Revent RVL80 handle taller ceilings or walk-in tub steam?

Evaluate how Revent RVL80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Revent RVL80
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 89 sq ft1 CFM/sq ft @ 89 CFM
Tall Bath (9-ft Ceiling)Up to 79 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 39 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.4 kWh/yr (~$0.38/yr)6.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.258.7 kWh/yr (~$9.39/yr)6.7 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Revent RVL80?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Ortech ODD-90-1 95 / 78.9 CFM 0.7 sones (-0.10) 13.2 CFM/W 4 in. diameter
Delta 80F 80 / 68.8 CFM 0.8 sones (Same) 9.5 CFM/W 4 in. diameter
Delta 80F-DGL 80 / 68.8 CFM 0.8 sones (Same) 9.5 CFM/W 4 in. diameter
Delta GBR80 80 / 68.8 CFM 0.8 sones (Same) 9.5 CFM/W 4 in. diameter
Delta 70BT 70 / 60 CFM 1.0 sones (+0.20) 10.6 CFM/W 4 in. diameter

Is Revent RVL80 sized right for your shower or tub room?

Check whether Revent RVL80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does Revent RVL80 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Revent RVL80 for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 39 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 89 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Revent RVL80?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Revent RVL80.

What acoustic sone tier does Revent RVL80 occupy in EPA filings?

With 0.8 sones at 0.1 in. w.g., Revent RVL80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Revent RVL80 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Revent RVL80 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Revent RVL80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVL80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVL80?

Revent RVL80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVL80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVL80's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Revent RVL80 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Revent RVL80 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Revent RVL80 in a bathroom remodel?

Avoid specifying Revent RVL80 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Revent RVL80 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Revent RVL80 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories