Certified by EPA ENERGY STAR, Ortech ODD-90-1 delivers 95 CFM free-air (78.9 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 13.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 78 sq ft (8-ft height) or 70 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-90-1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 95 / 78.9 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 13.2 CFM/W (#49/1,145)
- Static Retention
- 83.1% @ 0.25"
- Motor Draw
- 7.2 W (2.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Ortech ODD-90-1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 95 CFM open-air to 78.9 CFM at 0.25 in. w.g. (83.1% retention, 4.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places ODD-90-1 (series: ODD-90-1) (PD #3557062) among 27 Ortech entries qualified through 2024-08-02. Lighting kit: No. At 13.2 CFM/W (#49 of 1,145, top 4.5% of 1,145 rated models, more efficient than 95.5% of rated models, 8.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.2 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 63.1 kWh/yr (~$10.10/yr) continuously. Closest competing matches include Revent RVS80 (80.0 CFM) and Revent RVSH80 (80.0 CFM).
How noisy is Ortech ODD-90-1 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODD-90-1 measures 0.7 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Ortech ODD-90-1 airflow?
Connecting Ortech ODD-90-1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Ortech ODD-90-1 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODD-90-1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ODD-90-1 / ODD-90-1 | PD ID 3557062 (Qualified 2024-08-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (78.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Ortech ODD-90-1?
Calculated coverage metrics translate Ortech ODD-90-1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 78 sq ft | 1 CFM/sq ft @ 78.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 28 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.6 kWh/yr (~$0.42/yr) | 7.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 63.1 kWh/yr (~$10.10/yr) | 7.2 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Ortech ODD-90-1?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVS80 | 80 / 88.8 CFM | 0.6 sones (-0.10) | 12.6 CFM/W | 4 in. diameter |
| Revent RVSH80 | 80 / 88.8 CFM | 0.6 sones (-0.10) | 12.6 CFM/W | 4 in. diameter |
| Revent RVS110 | 110 / 119.2 CFM | 0.8 sones (+0.10) | 12.3 CFM/W | 4 in. diameter |
| Revent RVSH110 | 110 / 119.2 CFM | 0.8 sones (+0.10) | 12.3 CFM/W | 4 in. diameter |
| Revent RVL80 | 80 / 89 CFM | 0.8 sones (+0.10) | 12.0 CFM/W | 4 in. diameter |
Does Ortech ODD-90-1 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODD-90-1 percentage capacity without sending data.
What plumbing or duct constraints rule out Ortech ODD-90-1?
Compare where Ortech ODD-90-1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 28 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 78.9 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Ortech ODD-90-1?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODD-90-1.
How does Ortech ODD-90-1 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Ortech ODD-90-1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Ortech ODD-90-1 quiet enough for a primary bedroom bathroom?
At 0.7 sones, Ortech ODD-90-1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Ortech ODD-90-1 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Ortech ODD-90-1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-90-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech ODD-90-1?
Ortech ODD-90-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech ODD-90-1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-90-1's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Ortech ODD-90-1 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Ortech ODD-90-1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Ortech ODD-90-1 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Ortech ODD-90-1 lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)