Skip to main content
Grant Estimator

Ortech ODD-90-1 Exhaust Fan Specifications

ENERGY STAR PD #3557062 · Bathroom/Utility Room · Qualified 2024-08-02
Verified Specification Summary

Certified by EPA ENERGY STAR, Ortech ODD-90-1 delivers 95 CFM free-air (78.9 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 13.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 78 sq ft (8-ft height) or 70 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-90-1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
95 / 78.9 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
13.2 CFM/W (#49/1,145)
Static Retention
83.1% @ 0.25"
Motor Draw
7.2 W (2.6 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODD-90-1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 95 CFM open-air to 78.9 CFM at 0.25 in. w.g. (83.1% retention, 4.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places ODD-90-1 (series: ODD-90-1) (PD #3557062) among 27 Ortech entries qualified through 2024-08-02. Lighting kit: No. At 13.2 CFM/W (#49 of 1,145, top 4.5% of 1,145 rated models, more efficient than 95.5% of rated models, 8.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.2 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 63.1 kWh/yr (~$10.10/yr) continuously. Closest competing matches include Revent RVS80 (80.0 CFM) and Revent RVSH80 (80.0 CFM).

How noisy is Ortech ODD-90-1 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODD-90-1 measures 0.7 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

Why does rigid 4 in. diameter ducting protect Ortech ODD-90-1 airflow?

Connecting Ortech ODD-90-1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Ortech ODD-90-1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODD-90-1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODD-90-1 / ODD-90-1 PD ID 3557062 (Qualified 2024-08-02)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (78.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Ortech ODD-90-1?

Calculated coverage metrics translate Ortech ODD-90-1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Ortech ODD-90-1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 78 sq ft1 CFM/sq ft @ 78.9 CFM
Tall Bath (9-ft Ceiling)Up to 70 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 28 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.6 kWh/yr (~$0.42/yr)7.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.263.1 kWh/yr (~$10.10/yr)7.2 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Ortech ODD-90-1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVS80 80 / 88.8 CFM 0.6 sones (-0.10) 12.6 CFM/W 4 in. diameter
Revent RVSH80 80 / 88.8 CFM 0.6 sones (-0.10) 12.6 CFM/W 4 in. diameter
Revent RVS110 110 / 119.2 CFM 0.8 sones (+0.10) 12.3 CFM/W 4 in. diameter
Revent RVSH110 110 / 119.2 CFM 0.8 sones (+0.10) 12.3 CFM/W 4 in. diameter
Revent RVL80 80 / 89 CFM 0.8 sones (+0.10) 12.0 CFM/W 4 in. diameter

Does Ortech ODD-90-1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODD-90-1 percentage capacity without sending data.

What plumbing or duct constraints rule out Ortech ODD-90-1?

Compare where Ortech ODD-90-1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 28 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 78.9 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Ortech ODD-90-1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODD-90-1.

How does Ortech ODD-90-1 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Ortech ODD-90-1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Ortech ODD-90-1 quiet enough for a primary bedroom bathroom?

At 0.7 sones, Ortech ODD-90-1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Ortech ODD-90-1 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Ortech ODD-90-1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-90-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODD-90-1?

Ortech ODD-90-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODD-90-1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-90-1's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Ortech ODD-90-1 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Ortech ODD-90-1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Ortech ODD-90-1 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Ortech ODD-90-1 lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories