Skip to main content
Grant Estimator

Delta ITG50 Exhaust Fan Specifications

ENERGY STAR PD #2284209 · Bathroom/Utility Room · Qualified 2016-11-15
Verified Specification Summary

Homeowners specifying Delta ITG50 gain 50 CFM at 0.1 in. w.g. (40.7 CFM at 0.25 in. w.g.) where it registers #135 of 607 in quietness (0.7 sones) and delivers 12.3 CFM/W efficacy, venting bathrooms up to 40 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ITG50 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 40.7 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
12.3 CFM/W (#73/1,145)
Static Retention
81.4% @ 0.25"
Motor Draw
4.1 W (1.5 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta ITG50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 40.7 CFM at 0.25 in. w.g. (81.4% retention, 6.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Delta's 121-unit lineup, ITG50 (series: BreezIntegrity) carries PD #2284209 dating to 2016-11-15. Lighting kit: No. At 12.3 CFM/W (#73 of 1,145, top 6.6% of 1,145 rated models, more efficient than 93.4% of rated models, 7.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.1 watts, about 1.5 kWh/yr (~$0.24/yr at $0.16/kWh) for 1 hr/day shower timers or 35.9 kWh/yr (~$5.74/yr) continuously. Closest competing matches include Delta 50F-LED (50.0 CFM) and Delta ITG50LED (50.0 CFM).

What acoustic percentile does Delta ITG50 occupy among 1,145 bath blowers?

Inspect how Delta ITG50 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

Which exterior damper path suits Delta ITG50 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Delta ITG50 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Delta ITG50 acoustic and static metrics stand?

Compare Delta ITG50 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series ITG50 / BreezIntegrity PD ID 2284209 (Qualified 2016-11-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (40.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Delta ITG50 handle taller ceilings or walk-in tub steam?

Evaluate how Delta ITG50 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Delta ITG50
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 40 sq ft1 CFM/sq ft @ 40.7 CFM
Tall Bath (9-ft Ceiling)Up to 36 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)1.5 kWh/yr (~$0.24/yr)4.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.235.9 kWh/yr (~$5.74/yr)4.1 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Delta ITG50?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta 50F-LED 50 / 40.2 CFM 0.7 sones (Same) 10.8 CFM/W 4 in. diameter
Delta ITG50LED 50 / 40.2 CFM 0.7 sones (Same) 10.8 CFM/W 4 in. diameter
Hampton Bay 7114-02 50 / 36.9 CFM 1.0 sones (+0.30) 10.2 CFM/W 3 in. diameter
HomeWerks Worldwide 7114-02-HW 50 / 36.9 CFM 1.0 sones (+0.30) 10.2 CFM/W 3 in. diameter
Utilitech 7114-02-L 50 / 36.9 CFM 1.0 sones (+0.30) 10.2 CFM/W 3 in. diameter

Is Delta ITG50 sized right for your shower or tub room?

Check whether Delta ITG50 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying Delta ITG50?

Match Delta ITG50 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Supplementary continuous trickle ventilation
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Delta ITG50?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Delta ITG50.

What happens to Delta ITG50 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Delta ITG50 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Delta ITG50 sit on acoustic comfort for senior homeowners?

Measuring 0.7 sones, Delta ITG50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Delta ITG50 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Delta ITG50 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Delta ITG50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ITG50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta ITG50?

Delta ITG50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta ITG50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ITG50's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Delta ITG50 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta ITG50 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Delta ITG50 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta ITG50.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories