In EPA dataset 8dv7-nngq, Delta 50F-LED tests at 50 CFM free discharge (40.2 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 10.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 40 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 50F-LED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 40.2 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 10.8 CFM/W (#140/1,145)
- Static Retention
- 80.4% @ 0.25"
- Motor Draw
- 4.6 W (1.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Delta 50F-LED vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 40.2 CFM at 0.25 in. w.g. (80.4% retention, 7.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places 50F-LED (series: BreezIntegrity) (PD #2343318) among 121 Delta entries qualified through 2018-03-30. Lighting kit: Yes. At 10.8 CFM/W (#140 of 1,145, top 12.5% of 1,145 rated models, more efficient than 87.5% of rated models, 6.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.6 watts, about 1.7 kWh/yr (~$0.27/yr at $0.16/kWh) for 1 hr/day shower timers or 40.3 kWh/yr (~$6.45/yr) continuously. Closest competing matches include Delta ITG50LED (50.0 CFM) and Hampton Bay 7114-02 (50.0 CFM).
Does Delta 50F-LED fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta 50F-LED at 0.7 sones.
Why avoid unvented attic termination with Delta 50F-LED?
Under ASHRAE 62.2 best practice, Delta 50F-LED needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Delta 50F-LED?
Before cutting ceiling drywall or sizing attic transitions for Delta 50F-LED, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 50F-LED / BreezIntegrity | PD ID 2343318 (Qualified 2018-03-30) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (40.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Delta 50F-LED?
Bathroom ventilation sizing below maps Delta 50F-LED motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 40 sq ft | 1 CFM/sq ft @ 40.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 35 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 1.7 kWh/yr (~$0.27/yr) | 4.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 40.3 kWh/yr (~$6.45/yr) | 4.6 W x 8,760 hrs / 1,000 |
What peer models sit nearest Delta 50F-LED in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta 50F-LED.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta ITG50LED | 50 / 40.2 CFM | 0.7 sones (Same) | 10.8 CFM/W | 4 in. diameter |
| Hampton Bay 7114-02 | 50 / 36.9 CFM | 1.0 sones (+0.30) | 10.2 CFM/W | 3 in. diameter |
| HomeWerks Worldwide 7114-02-HW | 50 / 36.9 CFM | 1.0 sones (+0.30) | 10.2 CFM/W | 3 in. diameter |
| Utilitech 7114-02-L | 50 / 36.9 CFM | 1.0 sones (+0.30) | 10.2 CFM/W | 3 in. diameter |
| Delta ITG50 | 50 / 40.7 CFM | 0.7 sones (Same) | 12.3 CFM/W | 4 in. diameter |
What percentage of room demand does Delta 50F-LED cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta 50F-LED tested delivery.
When does Delta 50F-LED fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta 50F-LED.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 40.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 0.7 sones up to 40 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Delta 50F-LED?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta 50F-LED.
Which bathroom layouts should pick a larger blower than Delta 50F-LED?
Do not force Delta 50F-LED into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Delta 50F-LED retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Delta 50F-LED produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Delta 50F-LED disturb adjacent bedrooms during night use?
Acoustic measurement places Delta 50F-LED at 0.7 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Delta 50F-LED continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Delta 50F-LED draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Delta 50F-LED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 50F-LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta 50F-LED?
Delta 50F-LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta 50F-LED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 50F-LED's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Delta 50F-LED code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta 50F-LED clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)