Certified by EPA ENERGY STAR, HomeWerks Worldwide 7114-02-HW delivers 50 CFM free-air (36.9 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 10.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 36 sq ft (8-ft height) or 32 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7114-02-HW Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 36.9 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 10.2 CFM/W (#179/1,145)
- Static Retention
- 73.8% @ 0.25"
- Motor Draw
- 4.9 W (1.8 kWh/yr)
- Duct & Tier
- 3 in. diameter · Most Eff.

What does HomeWerks Worldwide 7114-02-HW vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.9 CFM at 0.25 in. w.g. (73.8% retention, 13.9 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms HomeWerks Worldwide 7114-02-HW (series: 7114-02-HW) under PD #3543503 (31 models registered, 2024-06-07). Lighting kit: No. At 10.2 CFM/W (#179 of 1,145, top 16.2% of 1,145 rated models, more efficient than 83.8% of rated models, 5.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.9 watts, about 1.8 kWh/yr (~$0.29/yr at $0.16/kWh) for 1 hr/day shower timers or 42.9 kWh/yr (~$6.86/yr) continuously. Closest competing matches include Hampton Bay 7114-02 (50.0 CFM) and Utilitech 7114-02-L (50.0 CFM).
How noisy is HomeWerks Worldwide 7114-02-HW compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while HomeWerks Worldwide 7114-02-HW measures 1.0 sones across the 1,145-model registry.
Why does rigid 3 in. diameter ducting protect HomeWerks Worldwide 7114-02-HW airflow?
Connecting HomeWerks Worldwide 7114-02-HW through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify HomeWerks Worldwide 7114-02-HW performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for HomeWerks Worldwide 7114-02-HW lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7114-02-HW / 7114-02-HW | PD ID 3543503 (Qualified 2024-06-07) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (36.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit HomeWerks Worldwide 7114-02-HW?
Calculated coverage metrics translate HomeWerks Worldwide 7114-02-HW airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 36 sq ft | 1 CFM/sq ft @ 36.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 32 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 1.8 kWh/yr (~$0.29/yr) | 4.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 42.9 kWh/yr (~$6.86/yr) | 4.9 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to HomeWerks Worldwide 7114-02-HW?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Hampton Bay 7114-02 | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| Utilitech 7114-02-L | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| Revent RVS50 | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |
| Revent RVSH50 | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |
| Delta 50F | 50 / 41.3 CFM | 1.0 sones (Same) | 11.6 CFM/W | 3 in. diameter |
Does HomeWerks Worldwide 7114-02-HW match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check HomeWerks Worldwide 7114-02-HW percentage capacity without sending data.
Who should not install HomeWerks Worldwide 7114-02-HW in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting HomeWerks Worldwide 7114-02-HW for residential use.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Supplementary continuous trickle ventilation
- Primary match: Collar pairs with 3 in. diameter duct straight outdoors
Which homeowner questions come up most for HomeWerks Worldwide 7114-02-HW?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around HomeWerks Worldwide 7114-02-HW.
What electrical efficiency and runtime kWh define HomeWerks Worldwide 7114-02-HW?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can HomeWerks Worldwide 7114-02-HW pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7114-02-HW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7114-02-HW?
HomeWerks Worldwide 7114-02-HW features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7114-02-HW's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7114-02-HW's safe coverage footprint from 50 sq ft to 44 sq ft.
Does HomeWerks Worldwide 7114-02-HW satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7114-02-HW clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is HomeWerks Worldwide 7114-02-HW undersized or poorly matched for a bath renovation?
Skip HomeWerks Worldwide 7114-02-HW if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check HomeWerks Worldwide 7114-02-HW CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, HomeWerks Worldwide 7114-02-HW registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.
How does HomeWerks Worldwide 7114-02-HW sound output compare to noisy contractor-grade fans?
Rated at 1.0 sones, HomeWerks Worldwide 7114-02-HW operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)