Delta 50F Exhaust Fan Specifications

ENERGY STAR PD #2285431 · Bathroom/Utility Room · Qualified 2016-12-02
Verified Specification Summary

Rated for 50 CFM open-air (41.3 CFM at 0.25 in. w.g.), Delta 50F registers #265 of 607 in quietness (1.0 sones) and delivers 11.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 41 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 50F Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 41.3 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
11.6 CFM/W (#104/1,145)
Static Retention
82.6% @ 0.25"
Motor Draw
4.3 W (1.6 kWh/yr)
Duct & Tier
3 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta 50F vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 41.3 CFM at 0.25 in. w.g. (82.6% retention, 5.1 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2285431 verifies 50F (series: BreezSlim) under Delta (121 listed models, qualified 2016-12-02). Lighting kit: No. At 11.6 CFM/W (#104 of 1,145, top 9.2% of 1,145 rated models, more efficient than 90.8% of rated models, 6.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 4.3 watts, about 1.6 kWh/yr (~$0.26/yr at $0.16/kWh) for 1 hr/day shower timers or 37.7 kWh/yr (~$6.03/yr) continuously. Closest competing matches include Hampton Bay 7114-02 (50.0 CFM) and HomeWerks Worldwide 7114-02-HW (50.0 CFM).

How does Delta 50F acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Delta 50F (1.0 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

How do flex elbows choke Delta 50F at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Delta 50F moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Delta 50F meet residential exhaust fan code specs?

Inspect Delta 50F mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series 50F / BreezSlim PD ID 2285431 (Qualified 2016-12-02)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (41.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Delta 50F airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta 50F tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta 50F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 41 sq ft1 CFM/sq ft @ 41.3 CFM
Tall Bath (9-ft Ceiling)Up to 36 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)1.6 kWh/yr (~$0.26/yr)4.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.237.7 kWh/yr (~$6.03/yr)4.3 W x 8,760 hrs / 1,000

Which competing models share Delta 50F airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hampton Bay 7114-02 50 / 36.9 CFM 1.0 sones (Same) 10.2 CFM/W 3 in. diameter
HomeWerks Worldwide 7114-02-HW 50 / 36.9 CFM 1.0 sones (Same) 10.2 CFM/W 3 in. diameter
Utilitech 7114-02-L 50 / 36.9 CFM 1.0 sones (Same) 10.2 CFM/W 3 in. diameter
Delta SLM50 50 / 41.3 CFM 1.0 sones (Same) 11.6 CFM/W 3 in. diameter
Revent RVS50 50 / 50 CFM 1.0 sones (Same) 9.1 CFM/W 4 in. diameter

How much airflow margin does Delta 50F give your bath?

Run a quick local room-volume check for Delta 50F by entering square footage and ceiling height to spot under-vented steam risks early.

What plumbing or duct constraints rule out Delta 50F?

Compare where Delta 50F excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 41 sq ft with 8-ft ceilings (36 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 3 in. diameter

What should homeowners verify first about Delta 50F?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta 50F.

Is Delta 50F quiet enough for a primary bedroom bathroom?

At 1.0 sones, Delta 50F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Delta 50F energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta 50F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 50F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta 50F?

Delta 50F features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta 50F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 50F's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta 50F serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta 50F supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Delta 50F for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta 50F lacks adequate reserve.

How does Delta 50F handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta 50F yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.

Sources