The Delta ITG70BT (BreezIntegrity) moves 70 CFM at 0.1 in. w.g. (60 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 10.6 CFM/W efficacy, sizing bathrooms up to 60 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ITG70BT Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 60 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 10.6 CFM/W (#152/1,145)
- Static Retention
- 85.7% @ 0.25"
- Motor Draw
- 6.6 W (2.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Delta ITG70BT vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60 CFM out of 70 CFM (85.7% retention, 2.0 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2254297 verifies ITG70BT (series: BreezIntegrity) under Delta (121 listed models, qualified 2015-12-01). Lighting kit: No. At 10.6 CFM/W (#152 of 1,145, top 13.7% of 1,145 rated models, more efficient than 86.3% of rated models, 5.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.6 watts, about 2.4 kWh/yr (~$0.38/yr at $0.16/kWh) for 1 hr/day shower timers or 57.8 kWh/yr (~$9.25/yr) continuously. Closest competing matches include Delta 70BT (70.0 CFM) and Revent RVL80 (80.0 CFM).
Where does Delta ITG70BT sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.
How does duct geometry alter Delta ITG70BT static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Delta ITG70BT?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta ITG70BT alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ITG70BT / BreezIntegrity | PD ID 2254297 (Qualified 2015-12-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Delta ITG70BT ventilate safely?
Sizing outputs below convert Delta ITG70BT tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.4 kWh/yr (~$0.38/yr) | 6.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 57.8 kWh/yr (~$9.25/yr) | 6.6 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Delta ITG70BT closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta 70BT | 70 / 60 CFM | 1.0 sones (Same) | 10.6 CFM/W | 4 in. diameter |
| Revent RVL80 | 80 / 89 CFM | 0.8 sones (-0.20) | 12.0 CFM/W | 4 in. diameter |
| Hampton Bay 7114-02 | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| HomeWerks Worldwide 7114-02-HW | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| Utilitech 7114-02-L | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
Will Delta ITG70BT clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Delta ITG70BT satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Where should contractors skip Delta ITG70BT on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta ITG70BT carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Delta ITG70BT?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta ITG70BT.
How does Delta ITG70BT score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta ITG70BT delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Delta ITG70BT?
Rule out Delta ITG70BT when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Delta ITG70BT capacity?
Because static drag at 0.25 in. w.g. lowers Delta ITG70BT from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Delta ITG70BT compared with a standard 3.0 sone builder fan?
Tested at 1.0 sones, Delta ITG70BT operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Delta ITG70BT consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Delta ITG70BT draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Delta ITG70BT pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ITG70BT's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta ITG70BT?
Delta ITG70BT features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta ITG70BT's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ITG70BT's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)