Skip to main content
Grant Estimator

Revent RVS110 Exhaust Fan Specifications

ENERGY STAR PD #4517837 · Bathroom/Utility Room · Qualified 2025-10-03
Verified Specification Summary

The Revent RVS110 (ReVent) moves 110 CFM at 0.1 in. w.g. (119.2 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones), and delivers 12.3 CFM/W efficacy, sizing bathrooms up to 119 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVS110 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 119.2 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
12.3 CFM/W (#73/1,145)
Static Retention
108.4% @ 0.25"
Motor Draw
8.9 W (3.2 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVS110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 119.2 CFM out of 110 CFM (108.4% retention, 20.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Revent RVS110 (series: ReVent) under PD #4517837 (40 models registered, 2025-10-03). Lighting kit: No. At 12.3 CFM/W (#73 of 1,145, top 6.6% of 1,145 rated models, more efficient than 93.4% of rated models, 7.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.9 watts, about 3.2 kWh/yr (~$0.51/yr at $0.16/kWh) for 1 hr/day shower timers or 78.0 kWh/yr (~$12.48/yr) continuously. Closest competing matches include DewStop - Breeze Easy BES110 (110.0 CFM) and Ortech ODD-110-1 (112.0 CFM).

Where does Revent RVS110 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.8 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

How does duct geometry alter Revent RVS110 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Revent RVS110?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Revent RVS110 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVS110 / ReVent PD ID 4517837 (Qualified 2025-10-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (119.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Revent RVS110 ventilate safely?

Sizing outputs below convert Revent RVS110 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Revent RVS110
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 119 sq ft1 CFM/sq ft @ 119.2 CFM
Tall Bath (9-ft Ceiling)Up to 105 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 69 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.2 kWh/yr (~$0.51/yr)8.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.278.0 kWh/yr (~$12.48/yr)8.9 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Revent RVS110 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
DewStop - Breeze Easy BES110 110 / 116.8 CFM 1.0 sones (+0.20) 11.9 CFM/W 4 in. diameter
Ortech ODD-110-1 112 / 94.5 CFM 1.0 sones (+0.20) 11.4 CFM/W 4 in. diameter
Ortech ODD-90-1 95 / 78.9 CFM 0.7 sones (-0.10) 13.2 CFM/W 4 in. diameter
Revent RVSH110 110 / 119.2 CFM 0.8 sones (Same) 12.3 CFM/W 4 in. diameter
KORA SBF90DC-MS 98.1 / N/A CFM 0.7 sones (-0.10) 10.7 CFM/W 4 in. diameter

Will Revent RVS110 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Revent RVS110 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Does Revent RVS110 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Revent RVS110 for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 69 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 119 sq ft with 8-ft ceilings (105 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Revent RVS110?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Revent RVS110.

Does duct resistance cut Revent RVS110 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Revent RVS110 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Revent RVS110 occupy in EPA filings?

With 0.8 sones at 0.1 in. w.g., Revent RVS110 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Revent RVS110 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Revent RVS110 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Revent RVS110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVS110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVS110?

Revent RVS110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVS110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVS110's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Revent RVS110 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Revent RVS110 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Revent RVS110 in a bathroom remodel?

Avoid specifying Revent RVS110 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories