Certified by EPA ENERGY STAR, Ortech ODD-110-1 delivers 112 CFM free-air (94.5 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 11.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 94 sq ft (8-ft height) or 84 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODD-110-1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 112 / 94.5 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 11.4 CFM/W (#115/1,145)
- Static Retention
- 84.4% @ 0.25"
- Motor Draw
- 9.8 W (3.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Ortech ODD-110-1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 112 CFM open-air to 94.5 CFM at 0.25 in. w.g. (84.4% retention, 3.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Ortech maintains 27 active ENERGY STAR blowers; ODD-110-1 (series: ODD-110-1) (PD #3557063) gained qualification on 2024-08-02. Lighting kit: No. At 11.4 CFM/W (#115 of 1,145, top 10.7% of 1,145 rated models, more efficient than 89.3% of rated models, 6.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.8 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 85.8 kWh/yr (~$13.73/yr) continuously. Closest competing matches include DewStop - Breeze Easy BES110 (110.0 CFM) and Revent RVL110 (110.0 CFM).
How noisy is Ortech ODD-110-1 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODD-110-1 measures 1.0 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Ortech ODD-110-1 airflow?
Connecting Ortech ODD-110-1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Ortech ODD-110-1 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODD-110-1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ODD-110-1 / ODD-110-1 | PD ID 3557063 (Qualified 2024-08-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (94.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Ortech ODD-110-1?
Calculated coverage metrics translate Ortech ODD-110-1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 84 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.6 kWh/yr (~$0.58/yr) | 9.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 85.8 kWh/yr (~$13.73/yr) | 9.8 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Ortech ODD-110-1?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| DewStop - Breeze Easy BES110 | 110 / 116.8 CFM | 1.0 sones (Same) | 11.9 CFM/W | 4 in. diameter |
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones (+0.20) | 11.3 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones (+0.20) | 11.3 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones (+0.20) | 11.2 CFM/W | 4 in. diameter |
| Revent RVS110 | 110 / 119.2 CFM | 0.8 sones (-0.20) | 12.3 CFM/W | 4 in. diameter |
Does Ortech ODD-110-1 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODD-110-1 percentage capacity without sending data.
Which bath layouts should avoid specifying Ortech ODD-110-1?
Match Ortech ODD-110-1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 44 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 94.5 CFM net static output
- Optimal use: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Ortech ODD-110-1?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODD-110-1.
What bathroom square footage can Ortech ODD-110-1 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Ortech ODD-110-1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Ortech ODD-110-1 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Ortech ODD-110-1.
What happens to Ortech ODD-110-1 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Ortech ODD-110-1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Ortech ODD-110-1 sit on acoustic comfort for senior homeowners?
Measuring 1.0 sones, Ortech ODD-110-1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Ortech ODD-110-1 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Ortech ODD-110-1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Ortech ODD-110-1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODD-110-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech ODD-110-1?
Ortech ODD-110-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech ODD-110-1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODD-110-1's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)