Rated for 110 CFM open-air (120.2 CFM at 0.25 in. w.g.), Revent RVL110 registers #380 of 607 in quietness (1.2 sones) and delivers 11.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 120 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVL110 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 120.2 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 11.3 CFM/W (#124/1,145)
- Static Retention
- 109.3% @ 0.25"
- Motor Draw
- 9.7 W (3.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Revent RVL110 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 120.2 CFM out of 110 CFM (109.3% retention, 21.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Revent RVL110 (series: ReVent) under PD #4517813 (40 models registered, 2025-10-03). Lighting kit: Yes. At 11.3 CFM/W (#124 of 1,145, top 11.0% of 1,145 rated models, more efficient than 89.0% of rated models, 6.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.7 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 85.0 kWh/yr (~$13.60/yr) continuously. Closest competing matches include DewStop - Breeze Easy BEL110 (110.0 CFM) and Ortech ODD-110-1 (112.0 CFM).
How does Revent RVL110 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Revent RVL110 (1.2 sones).
How do flex elbows choke Revent RVL110 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Revent RVL110 moving full rated CFM.
Does Revent RVL110 meet residential exhaust fan code specs?
Inspect Revent RVL110 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Revent (40 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RVL110 / ReVent | PD ID 4517813 (Qualified 2025-10-03) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (120.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Revent RVL110 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Revent RVL110 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.5 kWh/yr (~$0.56/yr) | 9.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 85.0 kWh/yr (~$13.60/yr) | 9.7 W x 8,760 hrs / 1,000 |
Which competing models share Revent RVL110 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones (Same) | 11.2 CFM/W | 4 in. diameter |
| Ortech ODD-110-1 | 112 / 94.5 CFM | 1.0 sones (-0.20) | 11.4 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BES110 | 110 / 116.8 CFM | 1.0 sones (-0.20) | 11.9 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 111.2 CFM | 1.1 sones (-0.10) | 9.5 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones (Same) | 11.3 CFM/W | 4 in. diameter |
How much airflow margin does Revent RVL110 give your bath?
Run a quick local room-volume check for Revent RVL110 by entering square footage and ceiling height to spot under-vented steam risks early.
When does Revent RVL110 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Revent RVL110.
Limitations & Who Should Skip
- Steam or walk-in tub room > 70 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 120 sq ft with 8-ft ceilings (106 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Revent RVL110?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Revent RVL110.
Will Revent RVL110 disturb adjacent bedrooms during night use?
Acoustic measurement places Revent RVL110 at 1.2 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Revent RVL110 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Revent RVL110 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Revent RVL110 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVL110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Revent RVL110?
Revent RVL110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Revent RVL110's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVL110's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Revent RVL110 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Revent RVL110 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Revent RVL110?
Do not force Revent RVL110 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Revent RVL110 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Revent RVL110 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)