Tested under HVI protocols, the Revent RVLH110 exhaust unit achieves 110 CFM at 0.1 in. w.g. (120.2 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones) and delivers 11.3 CFM/W efficacy, covering standard baths up to 120 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVLH110 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 120.2 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 11.3 CFM/W (#124/1,145)
- Static Retention
- 109.3% @ 0.25"
- Motor Draw
- 9.7 W (3.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Revent RVLH110 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 120.2 CFM out of 110 CFM (109.3% retention, 21.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places RVLH110 (series: ReVent) (PD #4514283) among 40 Revent entries qualified through 2025-10-03. Lighting kit: Yes. At 11.3 CFM/W (#124 of 1,145, top 11.0% of 1,145 rated models, more efficient than 89.0% of rated models, 6.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.7 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 85.0 kWh/yr (~$13.60/yr) continuously. Closest competing matches include DewStop - Breeze Easy BEL110 (110.0 CFM) and Ortech ODD-110-1 (112.0 CFM).
Where do Revent RVLH110 sones rank across EPA ENERGY STAR fans?
Comparing Revent RVLH110 (1.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Revent RVLH110 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Revent RVLH110, preventing premature peeling paint and mold growth.
How does Revent RVLH110 measure up on airflow and noise ratings?
Each row below breaks down Revent RVLH110 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Revent (40 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RVLH110 / ReVent | PD ID 4514283 (Qualified 2025-10-03) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (120.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Revent RVLH110 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.5 kWh/yr (~$0.56/yr) | 9.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 85.0 kWh/yr (~$13.60/yr) | 9.7 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Revent RVLH110?
Compare Revent RVLH110 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones (Same) | 11.2 CFM/W | 4 in. diameter |
| Ortech ODD-110-1 | 112 / 94.5 CFM | 1.0 sones (-0.20) | 11.4 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BES110 | 110 / 116.8 CFM | 1.0 sones (-0.20) | 11.9 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 111.2 CFM | 1.1 sones (-0.10) | 9.5 CFM/W | 4 in. diameter |
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones (Same) | 11.3 CFM/W | 4 in. diameter |
Can you size Revent RVLH110 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Revent RVLH110 verified capacity.
What plumbing or duct constraints rule out Revent RVLH110?
Compare where Revent RVLH110 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 120.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 1.2 sones up to 120 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Revent RVLH110?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Revent RVLH110.
Is Revent RVLH110 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Revent RVLH110 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVLH110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Revent RVLH110?
Revent RVLH110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Revent RVLH110's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVLH110's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Revent RVLH110 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Revent RVLH110 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Revent RVLH110 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Revent RVLH110 lacks adequate reserve.
How does Revent RVLH110 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Revent RVLH110 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Revent RVLH110 quiet enough for a primary bedroom bathroom?
At 1.2 sones, Revent RVLH110 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)