Skip to main content
Grant Estimator

Delta VDBFRS200 Exhaust Fan Specifications

ENERGY STAR PD #2406842 · In-line (single-port) · Qualified 2023-01-13
Verified Specification Summary

Homeowners specifying Delta VDBFRS200 gain 200 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it omits a published 0.1-inch sone rating and delivers 5.3 CFM/W efficacy, venting bathrooms up to 200 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta VDBFRS200 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
200 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.3 CFM/W (#494/1,145)
Static Retention
0.1" test only
Motor Draw
37.7 W (13.8 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta VDBFRS200 vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta VDBFRS200 (EPA filing PD #2406842) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Delta maintains 121 active ENERGY STAR blowers; VDBFRS200 (series: BreezFresh) (PD #2406842) gained qualification on 2023-01-13. Lighting kit: No. At 5.3 CFM/W (#494 of 1,145, top 43.5% of 1,145 rated models, more efficient than 56.5% of rated models, 0.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 37.7 watts, about 13.8 kWh/yr (~$2.21/yr at $0.16/kWh) for 1 hr/day shower timers or 330.3 kWh/yr (~$52.85/yr) continuously. Closest competing matches include Fantech FreshFlow(579865) (200.0 CFM) and Broan L200EL (200.0 CFM).

Which exterior damper path suits Delta VDBFRS200 best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Delta VDBFRS200 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Delta VDBFRS200 acoustic and static metrics stand?

Compare Delta VDBFRS200 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series VDBFRS200 / BreezFresh PD ID 2406842 (Qualified 2023-01-13)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (200 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Delta VDBFRS200 handle taller ceilings or walk-in tub steam?

Evaluate how Delta VDBFRS200 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Delta VDBFRS200
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 200 sq ft1 CFM/sq ft @ 200 CFM
Tall Bath (9-ft Ceiling)Up to 177 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 150 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)13.8 kWh/yr (~$2.21/yr)37.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2330.3 kWh/yr (~$52.85/yr)37.7 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Delta VDBFRS200?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Fantech FreshFlow(579865) 200 / N/A CFM Unpublished 5.4 CFM/W 6 in. diameter
Broan L200EL 200 / N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Broan L150E 210 / 175.2 CFM Unpublished 5.0 CFM/W 8 in. diameter
Aprilaire 8145 190 / N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Aprilaire 8145NC 190 / N/A CFM Unpublished 4.4 CFM/W 6 in. diameter

Is Delta VDBFRS200 sized right for your shower or tub room?

Check whether Delta VDBFRS200 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

When does Delta VDBFRS200 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta VDBFRS200.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 150 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 200 CFM net static output
  • Target scenario: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Delta VDBFRS200?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Delta VDBFRS200.

Is Delta VDBFRS200 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta VDBFRS200 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Delta VDBFRS200?

Do not force Delta VDBFRS200 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Delta VDBFRS200 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Delta VDBFRS200 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will Delta VDBFRS200 disturb adjacent bedrooms during night use?

Acoustic measurement places Delta VDBFRS200 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Delta VDBFRS200 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Delta VDBFRS200 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Delta VDBFRS200 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta VDBFRS200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta VDBFRS200?

Delta VDBFRS200 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta VDBFRS200's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta VDBFRS200's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories