In EPA dataset 8dv7-nngq, Aprilaire 8145NC tests at 190 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 190 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Aprilaire 8145NC Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 190 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 43.2 W (15.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Aprilaire 8145NC vs. 1,145-Model ENERGY STAR Benchmarks show?
Aprilaire 8145NC (EPA filing PD #4667275) omits a published 0.1-inch sone acoustic rating in its current In-line (multi-port) certification record.
Free-discharge delivery reaches 190 CFM (#64 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Aprilaire registers 3 certified models, with SKU 8145NC (series: 8145) (PD #4667275) certified since 2026-07-08. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 43.2 watts, about 15.8 kWh/yr (~$2.53/yr at $0.16/kWh) for 1 hr/day shower timers or 378.4 kWh/yr (~$60.54/yr) continuously. Closest competing matches include Zephyr AK8400BS-ES (190.0 CFM) and Broan ALT4306SS (190.0 CFM).
Why avoid unvented attic termination with Aprilaire 8145NC?
Under ASHRAE 62.2 best practice, Aprilaire 8145NC needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Aprilaire 8145NC?
Before cutting ceiling drywall or sizing attic transitions for Aprilaire 8145NC, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Aprilaire (3 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 8145NC / 8145 | PD ID 4667275 (Qualified 2026-07-08) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (190 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Aprilaire 8145NC?
Bathroom ventilation sizing below maps Aprilaire 8145NC motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 190 sq ft | 1 CFM/sq ft @ 190 CFM |
| Tall Bath (9-ft Ceiling) | Up to 168 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 140 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 15.8 kWh/yr (~$2.53/yr) | 43.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 378.4 kWh/yr (~$60.54/yr) | 43.2 W x 8,760 hrs / 1,000 |
What peer models sit nearest Aprilaire 8145NC in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Aprilaire 8145NC.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Zephyr AK8400BS-ES | 190 / N/A CFM | 2.0 sones | 3.9 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 190 / N/A CFM | Unpublished | 3.7 CFM/W | 3.25 x 14 in. rectangular |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Broan L200EL | 200 / N/A CFM | Unpublished | 4.0 CFM/W | 8 in. diameter |
| Delta VDBFRS200HT | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
What percentage of room demand does Aprilaire 8145NC cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Aprilaire 8145NC tested delivery.
Where should contractors skip Aprilaire 8145NC on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Aprilaire 8145NC carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 190 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 190 sq ft
- Works well for: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Aprilaire 8145NC?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Aprilaire 8145NC.
How loud is Aprilaire 8145NC compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Aprilaire 8145NC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Aprilaire 8145NC consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Aprilaire 8145NC draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Aprilaire 8145NC pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Aprilaire 8145NC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Aprilaire 8145NC?
Aprilaire 8145NC features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Aprilaire 8145NC's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Aprilaire 8145NC's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Aprilaire 8145NC score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Aprilaire 8145NC delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Aprilaire 8145NC?
Rule out Aprilaire 8145NC when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Aprilaire 8145NC capacity?
Because static drag at 0.25 in. w.g. lowers Aprilaire 8145NC from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)