Zephyr AK8400BS-ES Exhaust Fan Specifications

ENERGY STAR PD #2454333 · Range Hood · Qualified 2023-03-10
Verified Specification Summary

Tested under HVI protocols, the Zephyr AK8400BS-ES exhaust unit achieves 190 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), registers #522 of 607 in quietness (2.0 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 190 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Zephyr AK8400BS-ES Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
190 / N/A CFM
Noise @ 0.1"
2.0 sones (#522/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
0.1" test only
Motor Draw
48.7 W (17.8 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Zephyr AK8400BS-ES vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Free-discharge delivery reaches 190 CFM (#64 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Zephyr's 3-unit lineup, AK8400BS-ES (series: RANGE HOOD) carries PD #2454333 dating to 2023-03-10. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 48.7 watts, about 17.8 kWh/yr (~$2.85/yr at $0.16/kWh) for 1 hr/day shower timers or 426.6 kWh/yr (~$68.26/yr) continuously. Closest competing matches include Broan ALT4306SS (190.0 CFM) and Aprilaire 8145 (190.0 CFM).

Where do Zephyr AK8400BS-ES sones rank across EPA ENERGY STAR fans?

Comparing Zephyr AK8400BS-ES (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.0 sone: 2 sones (99th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.0 sone: 2 sones (P99)

What attic duct routing preserves Zephyr AK8400BS-ES CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Zephyr AK8400BS-ES, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Zephyr AK8400BS-ES measure up on airflow and noise ratings?

Each row below breaks down Zephyr AK8400BS-ES certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Zephyr (3 models) ENERGY STAR Certified Partner
Model Number & Series AK8400BS-ES / RANGE HOOD PD ID 2454333 (Qualified 2023-03-10)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (190 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Zephyr AK8400BS-ES CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Zephyr AK8400BS-ES
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 190 sq ft1 CFM/sq ft @ 190 CFM
Tall Bath (9-ft Ceiling)Up to 168 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 140 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)17.8 kWh/yr (~$2.85/yr)48.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2426.6 kWh/yr (~$68.26/yr)48.7 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Zephyr AK8400BS-ES?

Compare Zephyr AK8400BS-ES side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan ALT4306SS 190 / N/A CFM Unpublished 3.7 CFM/W 3.25 x 14 in. rectangular
Aprilaire 8145 190 / N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Aprilaire 8145NC 190 / N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Broan L200EL 200 / N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter

Can you size Zephyr AK8400BS-ES for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Zephyr AK8400BS-ES verified capacity.

When does Zephyr AK8400BS-ES fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Zephyr AK8400BS-ES.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 190 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 2.0 sones up to 190 sq ft
  • Target scenario: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Zephyr AK8400BS-ES?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Zephyr AK8400BS-ES.

Does running Zephyr AK8400BS-ES continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Zephyr AK8400BS-ES draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Zephyr AK8400BS-ES pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Zephyr AK8400BS-ES's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Zephyr AK8400BS-ES?

Zephyr AK8400BS-ES features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Zephyr AK8400BS-ES's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Zephyr AK8400BS-ES's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Zephyr AK8400BS-ES code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Zephyr AK8400BS-ES clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Zephyr AK8400BS-ES?

Do not force Zephyr AK8400BS-ES into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Zephyr AK8400BS-ES retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Zephyr AK8400BS-ES produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will Zephyr AK8400BS-ES disturb adjacent bedrooms during night use?

Acoustic measurement places Zephyr AK8400BS-ES at 2.0 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories