The Panasonic FV-30VQ3 (WhisperCeiling) moves 280 CFM at 0.1 in. w.g. (254.4 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 4.4 CFM/W efficacy, sizing bathrooms up to 254 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-30VQ3 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 280 / 254.4 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 90.9% @ 0.25"
- Motor Draw
- 63.6 W (23.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Panasonic FV-30VQ3 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 254.4 CFM out of 280 CFM (90.9% retention, 3.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Panasonic registers 92 certified models, with SKU FV-30VQ3 (series: WhisperCeiling) (PD #3892183) certified since 2024-12-20. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 63.6 watts, about 23.2 kWh/yr (~$3.71/yr at $0.16/kWh) for 1 hr/day shower timers or 557.1 kWh/yr (~$89.14/yr) continuously. Closest competing matches include Fantech FR 150 (411334) (280.0 CFM) and S&P TD-150S (270.0 CFM).
Where does Panasonic FV-30VQ3 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.
How does duct geometry alter Panasonic FV-30VQ3 static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Panasonic FV-30VQ3?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Panasonic FV-30VQ3 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-30VQ3 / WhisperCeiling | PD ID 3892183 (Qualified 2024-12-20) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (254.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Panasonic FV-30VQ3 ventilate safely?
Sizing outputs below convert Panasonic FV-30VQ3 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 254 sq ft | 1 CFM/sq ft @ 254.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 226 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 204 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 23.2 kWh/yr (~$3.71/yr) | 63.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 557.1 kWh/yr (~$89.14/yr) | 63.6 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Panasonic FV-30VQ3 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Fantech FR 150 (411334) | 280 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |
| S&P TD-150S | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| Broan L250E | 270 / 245 CFM | Unpublished | 4.6 CFM/W | 8 in. diameter |
| Broan L300EL | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| Dayton 3DPE6A | 270 / N/A CFM | 2.2 sones (+0.20) | 4.3 CFM/W | 8 x 8 in. rectangular |
Will Panasonic FV-30VQ3 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Panasonic FV-30VQ3 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Which bath layouts should avoid specifying Panasonic FV-30VQ3?
Match Panasonic FV-30VQ3 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 204 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 254 sq ft with 8-ft ceilings (226 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern Panasonic FV-30VQ3?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Panasonic FV-30VQ3.
What bathroom square footage can Panasonic FV-30VQ3 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-30VQ3 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Panasonic FV-30VQ3 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic FV-30VQ3.
What happens to Panasonic FV-30VQ3 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Panasonic FV-30VQ3 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Panasonic FV-30VQ3 sit on acoustic comfort for senior homeowners?
Measuring 2.0 sones, Panasonic FV-30VQ3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Panasonic FV-30VQ3 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Panasonic FV-30VQ3 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Panasonic FV-30VQ3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-30VQ3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-30VQ3?
Panasonic FV-30VQ3 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-30VQ3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-30VQ3's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)