Rated for 270 CFM open-air (unpublished 0.25 in. w.g. output), S&P TD-150S omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 270 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P TD-150S Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 270 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 60.0 W (21.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does S&P TD-150S vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P TD-150S (EPA filing PD #2395000) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 270 CFM (#23 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places TD-150S (series: TD Silent) (PD #2395000) among 29 S&P entries qualified through 2022-04-22. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 60.0 watts, about 21.9 kWh/yr (~$3.50/yr at $0.16/kWh) for 1 hr/day shower timers or 525.6 kWh/yr (~$84.10/yr) continuously. Closest competing matches include Broan L250E (270.0 CFM) and Broan L300EL (270.0 CFM).
How do flex elbows choke S&P TD-150S at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps S&P TD-150S moving full rated CFM.
Does S&P TD-150S meet residential exhaust fan code specs?
Inspect S&P TD-150S mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-150S / TD Silent | PD ID 2395000 (Qualified 2022-04-22) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (270 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match S&P TD-150S airflow output?
Annual electricity figures and room square-footage ceilings below reflect S&P TD-150S tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 270 sq ft | 1 CFM/sq ft @ 270 CFM |
| Tall Bath (9-ft Ceiling) | Up to 240 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 220 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 21.9 kWh/yr (~$3.50/yr) | 60.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 525.6 kWh/yr (~$84.10/yr) | 60.0 W x 8,760 hrs / 1,000 |
Which competing models share S&P TD-150S airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan L250E | 270 / 245 CFM | Unpublished | 4.6 CFM/W | 8 in. diameter |
| Broan L300EL | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| Dayton 5AE72A | 240 / N/A CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| Greenheck SP-A200 | 240 / 224 CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| Panasonic FV-30VQ3 | 280 / 254.4 CFM | 2.0 sones | 4.4 CFM/W | 6 in. diameter |
How much airflow margin does S&P TD-150S give your bath?
Run a quick local room-volume check for S&P TD-150S by entering square footage and ceiling height to spot under-vented steam risks early.
Where should contractors skip S&P TD-150S on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P TD-150S carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 220 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 270 sq ft with 8-ft ceilings (240 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about S&P TD-150S?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to S&P TD-150S.
What duct and room conditions disqualify S&P TD-150S?
Rule out S&P TD-150S when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke S&P TD-150S capacity?
Because static drag at 0.25 in. w.g. lowers S&P TD-150S from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is S&P TD-150S compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, S&P TD-150S produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does S&P TD-150S consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, S&P TD-150S draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can S&P TD-150S pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P TD-150S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P TD-150S?
S&P TD-150S features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P TD-150S's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P TD-150S's safe coverage footprint from 50 sq ft to 44 sq ft.
How does S&P TD-150S score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P TD-150S delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)