Skip to main content
Grant Estimator

Fantech FG 6 (40406) Exhaust Fan Specifications

ENERGY STAR PD #2394296 · In-line (single-port) · Qualified 2022-04-01
Verified Specification Summary

Rated for 260 CFM open-air (unpublished 0.25 in. w.g. output), Fantech FG 6 (40406) omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 260 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 6 (40406) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
260 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
0.1" test only
Motor Draw
66.7 W (24.3 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech FG 6 (40406) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 6 (40406) (EPA filing PD #2394296) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Fantech's 52-unit lineup, FG 6 (40406) (series: FG Series) carries PD #2394296 dating to 2022-04-01. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 66.7 watts, about 24.3 kWh/yr (~$3.89/yr at $0.16/kWh) for 1 hr/day shower timers or 584.3 kWh/yr (~$93.49/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).

How do flex elbows choke Fantech FG 6 (40406) at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Fantech FG 6 (40406) moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Fantech FG 6 (40406) meet residential exhaust fan code specs?

Inspect Fantech FG 6 (40406) mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series FG 6 (40406) / FG Series PD ID 2394296 (Qualified 2022-04-01)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (260 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Fantech FG 6 (40406) airflow output?

Annual electricity figures and room square-footage ceilings below reflect Fantech FG 6 (40406) tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Fantech FG 6 (40406)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 260 sq ft1 CFM/sq ft @ 260 CFM
Tall Bath (9-ft Ceiling)Up to 231 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 210 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)24.3 kWh/yr (~$3.89/yr)66.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2584.3 kWh/yr (~$93.49/yr)66.7 W x 8,760 hrs / 1,000

Which competing models share Fantech FG 6 (40406) airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 5AE72A 240 / N/A CFM 1.4 sones 4.3 CFM/W 8 x 8 in. rectangular
Greenheck SP-A200 240 / 224 CFM 1.4 sones 4.3 CFM/W 8 x 8 in. rectangular
S&P TD-150 260 / N/A CFM Unpublished 4.3 CFM/W 6 in. diameter
Broan L300EL 270 / N/A CFM Unpublished 3.9 CFM/W 8 in. diameter
S&P TD-150S 270 / N/A CFM Unpublished 4.5 CFM/W 6 in. diameter

How much airflow margin does Fantech FG 6 (40406) give your bath?

Run a quick local room-volume check for Fantech FG 6 (40406) by entering square footage and ceiling height to spot under-vented steam risks early.

Does Fantech FG 6 (40406) suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech FG 6 (40406) for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 210 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 260 sq ft with 8-ft ceilings (231 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about Fantech FG 6 (40406)?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Fantech FG 6 (40406).

Who should NOT install Fantech FG 6 (40406) in a bathroom remodel?

Avoid specifying Fantech FG 6 (40406) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Fantech FG 6 (40406) airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech FG 6 (40406) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Fantech FG 6 (40406) occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech FG 6 (40406) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Fantech FG 6 (40406) add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Fantech FG 6 (40406) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Fantech FG 6 (40406) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 6 (40406)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech FG 6 (40406)?

Fantech FG 6 (40406) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech FG 6 (40406)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 6 (40406)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Does Fantech FG 6 (40406) pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech FG 6 (40406) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories