In EPA dataset 8dv7-nngq, S&P TD-150 tests at 260 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 260 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P TD-150 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 260 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 60.5 W (22.1 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does S&P TD-150 vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P TD-150 (EPA filing PD #2395001) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
S&P maintains 29 active ENERGY STAR blowers; TD-150 (series: TD Mixvent) (PD #2395001) gained qualification on 2022-04-22. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 60.5 watts, about 22.1 kWh/yr (~$3.54/yr at $0.16/kWh) for 1 hr/day shower timers or 530.0 kWh/yr (~$84.80/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).
Why avoid unvented attic termination with S&P TD-150?
Under ASHRAE 62.2 best practice, S&P TD-150 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern S&P TD-150?
Before cutting ceiling drywall or sizing attic transitions for S&P TD-150, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-150 / TD Mixvent | PD ID 2395001 (Qualified 2022-04-22) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (260 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit S&P TD-150?
Bathroom ventilation sizing below maps S&P TD-150 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 260 sq ft | 1 CFM/sq ft @ 260 CFM |
| Tall Bath (9-ft Ceiling) | Up to 231 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 210 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 22.1 kWh/yr (~$3.54/yr) | 60.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 530.0 kWh/yr (~$84.80/yr) | 60.5 W x 8,760 hrs / 1,000 |
What peer models sit nearest S&P TD-150 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P TD-150.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Dayton 5AE72A | 240 / N/A CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| Greenheck SP-A200 | 240 / 224 CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| Fantech FG 6 (40406) | 260 / N/A CFM | Unpublished | 3.9 CFM/W | 6 in. diameter |
| Fantech FGC 6 (40381) | 260 / N/A CFM | Unpublished | 3.9 CFM/W | 6 in. diameter |
| Fantech PB 270-2 (40572) | 260 / N/A CFM | Unpublished | 3.9 CFM/W | 6 in. diameter |
What percentage of room demand does S&P TD-150 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P TD-150 tested delivery.
Where should contractors skip S&P TD-150 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P TD-150 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 260 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 260 sq ft
- Works well for: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for S&P TD-150?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P TD-150.
How much power does S&P TD-150 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, S&P TD-150 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can S&P TD-150 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P TD-150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P TD-150?
S&P TD-150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P TD-150's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P TD-150's safe coverage footprint from 50 sq ft to 44 sq ft.
How does S&P TD-150 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P TD-150 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify S&P TD-150?
Rule out S&P TD-150 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke S&P TD-150 capacity?
Because static drag at 0.25 in. w.g. lowers S&P TD-150 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is S&P TD-150 compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, S&P TD-150 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)