In EPA dataset 8dv7-nngq, Fantech PB 270L7V-2 (44946) tests at 260 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 260 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB 270L7V-2 (44946) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 260 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 66.7 W (24.3 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Fantech PB 270L7V-2 (44946) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech PB 270L7V-2 (44946) (EPA filing PD #2394308) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Fantech registers 52 certified models, with SKU PB 270L7V-2 (44946) (series: PB 270 Series) (PD #2394308) certified since 2022-04-01. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 66.7 watts, about 24.3 kWh/yr (~$3.89/yr at $0.16/kWh) for 1 hr/day shower timers or 584.3 kWh/yr (~$93.49/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).
Why avoid unvented attic termination with Fantech PB 270L7V-2 (44946)?
Under ASHRAE 62.2 best practice, Fantech PB 270L7V-2 (44946) needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Fantech PB 270L7V-2 (44946)?
Before cutting ceiling drywall or sizing attic transitions for Fantech PB 270L7V-2 (44946), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PB 270L7V-2 (44946) / PB 270 Series | PD ID 2394308 (Qualified 2022-04-01) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (260 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Fantech PB 270L7V-2 (44946)?
Bathroom ventilation sizing below maps Fantech PB 270L7V-2 (44946) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 260 sq ft | 1 CFM/sq ft @ 260 CFM |
| Tall Bath (9-ft Ceiling) | Up to 231 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 210 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 24.3 kWh/yr (~$3.89/yr) | 66.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 584.3 kWh/yr (~$93.49/yr) | 66.7 W x 8,760 hrs / 1,000 |
What peer models sit nearest Fantech PB 270L7V-2 (44946) in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech PB 270L7V-2 (44946).
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Dayton 5AE72A | 240 / N/A CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| Greenheck SP-A200 | 240 / 224 CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| S&P TD-150 | 260 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |
| Broan L300EL | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| S&P TD-150S | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
What percentage of room demand does Fantech PB 270L7V-2 (44946) cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech PB 270L7V-2 (44946) tested delivery.
When does Fantech PB 270L7V-2 (44946) fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech PB 270L7V-2 (44946).
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 260 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 260 sq ft
- Target scenario: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Fantech PB 270L7V-2 (44946)?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech PB 270L7V-2 (44946).
Which bathroom layouts should pick a larger blower than Fantech PB 270L7V-2 (44946)?
Do not force Fantech PB 270L7V-2 (44946) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Fantech PB 270L7V-2 (44946) retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Fantech PB 270L7V-2 (44946) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Will Fantech PB 270L7V-2 (44946) disturb adjacent bedrooms during night use?
Acoustic measurement places Fantech PB 270L7V-2 (44946) at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Fantech PB 270L7V-2 (44946) continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Fantech PB 270L7V-2 (44946) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Fantech PB 270L7V-2 (44946) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB 270L7V-2 (44946)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech PB 270L7V-2 (44946)?
Fantech PB 270L7V-2 (44946) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech PB 270L7V-2 (44946)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB 270L7V-2 (44946)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Is Fantech PB 270L7V-2 (44946) code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech PB 270L7V-2 (44946) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.