Skip to main content
Grant Estimator

Fantech PB 270L710-2 (44948) Exhaust Fan Specifications

ENERGY STAR PD #2394310 · Bathroom/Utility Room · Qualified 2022-04-01
Verified Specification Summary

Rated for 260 CFM open-air (unpublished 0.25 in. w.g. output), Fantech PB 270L710-2 (44948) omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 260 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB 270L710-2 (44948) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
260 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
0.1" test only
Motor Draw
66.7 W (24.3 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech PB 270L710-2 (44948) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech PB 270L710-2 (44948) (EPA filing PD #2394310) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2394310 verifies PB 270L710-2 (44948) (series: PB 270 Series) under Fantech (52 listed models, qualified 2022-04-01). Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 66.7 watts, about 24.3 kWh/yr (~$3.89/yr at $0.16/kWh) for 1 hr/day shower timers or 584.3 kWh/yr (~$93.49/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).

How do flex elbows choke Fantech PB 270L710-2 (44948) at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Fantech PB 270L710-2 (44948) moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Fantech PB 270L710-2 (44948) meet residential exhaust fan code specs?

Inspect Fantech PB 270L710-2 (44948) mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series PB 270L710-2 (44948) / PB 270 Series PD ID 2394310 (Qualified 2022-04-01)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (260 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Fantech PB 270L710-2 (44948) airflow output?

Annual electricity figures and room square-footage ceilings below reflect Fantech PB 270L710-2 (44948) tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Fantech PB 270L710-2 (44948)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 260 sq ft1 CFM/sq ft @ 260 CFM
Tall Bath (9-ft Ceiling)Up to 231 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 210 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)24.3 kWh/yr (~$3.89/yr)66.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2584.3 kWh/yr (~$93.49/yr)66.7 W x 8,760 hrs / 1,000

Which competing models share Fantech PB 270L710-2 (44948) airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 5AE72A 240 / N/A CFM 1.4 sones 4.3 CFM/W 8 x 8 in. rectangular
Greenheck SP-A200 240 / 224 CFM 1.4 sones 4.3 CFM/W 8 x 8 in. rectangular
S&P TD-150 260 / N/A CFM Unpublished 4.3 CFM/W 6 in. diameter
Broan L300EL 270 / N/A CFM Unpublished 3.9 CFM/W 8 in. diameter
S&P TD-150S 270 / N/A CFM Unpublished 4.5 CFM/W 6 in. diameter

How much airflow margin does Fantech PB 270L710-2 (44948) give your bath?

Run a quick local room-volume check for Fantech PB 270L710-2 (44948) by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Fantech PB 270L710-2 (44948) on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Fantech PB 270L710-2 (44948) carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 210 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 260 sq ft with 8-ft ceilings (231 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about Fantech PB 270L710-2 (44948)?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Fantech PB 270L710-2 (44948).

Will long attic ducting choke Fantech PB 270L710-2 (44948) capacity?

Because static drag at 0.25 in. w.g. lowers Fantech PB 270L710-2 (44948) from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Fantech PB 270L710-2 (44948) compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Fantech PB 270L710-2 (44948) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Fantech PB 270L710-2 (44948) consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Fantech PB 270L710-2 (44948) draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Fantech PB 270L710-2 (44948) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB 270L710-2 (44948)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech PB 270L710-2 (44948)?

Fantech PB 270L710-2 (44948) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech PB 270L710-2 (44948)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB 270L710-2 (44948)'s safe coverage footprint from 50 sq ft to 44 sq ft.

How does Fantech PB 270L710-2 (44948) score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Fantech PB 270L710-2 (44948) delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Fantech PB 270L710-2 (44948)?

Rule out Fantech PB 270L710-2 (44948) when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories