Certified by EPA ENERGY STAR, Fantech PB 270-2 (40572) delivers 260 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 260 sq ft (8-ft height) or 231 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB 270-2 (40572) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 260 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 66.7 W (24.3 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Fantech PB 270-2 (40572) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech PB 270-2 (40572) (EPA filing PD #2394297) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Fantech registers 52 certified models, with SKU PB 270-2 (40572) (series: PB 270 Series) (PD #2394297) certified since 2022-04-01. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 66.7 watts, about 24.3 kWh/yr (~$3.89/yr at $0.16/kWh) for 1 hr/day shower timers or 584.3 kWh/yr (~$93.49/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).
Why does rigid 6 in. diameter ducting protect Fantech PB 270-2 (40572) airflow?
Connecting Fantech PB 270-2 (40572) through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Fantech PB 270-2 (40572) performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech PB 270-2 (40572) lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PB 270-2 (40572) / PB 270 Series | PD ID 2394297 (Qualified 2022-04-01) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (260 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Fantech PB 270-2 (40572)?
Calculated coverage metrics translate Fantech PB 270-2 (40572) airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 260 sq ft | 1 CFM/sq ft @ 260 CFM |
| Tall Bath (9-ft Ceiling) | Up to 231 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 210 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 24.3 kWh/yr (~$3.89/yr) | 66.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 584.3 kWh/yr (~$93.49/yr) | 66.7 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Fantech PB 270-2 (40572)?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Dayton 5AE72A | 240 / N/A CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| Greenheck SP-A200 | 240 / 224 CFM | 1.4 sones | 4.3 CFM/W | 8 x 8 in. rectangular |
| S&P TD-150 | 260 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |
| Broan L300EL | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| S&P TD-150S | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
Does Fantech PB 270-2 (40572) match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech PB 270-2 (40572) percentage capacity without sending data.
Who should not install Fantech PB 270-2 (40572) in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Fantech PB 270-2 (40572) for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 210 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 260 CFM net static output
- Primary match: Collar pairs with 6 in. diameter duct straight outdoors
Which homeowner questions come up most for Fantech PB 270-2 (40572)?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech PB 270-2 (40572).
When is Fantech PB 270-2 (40572) undersized or poorly matched for a bath renovation?
Skip Fantech PB 270-2 (40572) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Fantech PB 270-2 (40572) CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Fantech PB 270-2 (40572) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does Fantech PB 270-2 (40572) sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Fantech PB 270-2 (40572) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Fantech PB 270-2 (40572)?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Fantech PB 270-2 (40572) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB 270-2 (40572)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech PB 270-2 (40572)?
Fantech PB 270-2 (40572) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech PB 270-2 (40572)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB 270-2 (40572)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Fantech PB 270-2 (40572) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Fantech PB 270-2 (40572) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)