Skip to main content
Grant Estimator

Fantech PB 270L10V2 (44947) Exhaust Fan Specifications

ENERGY STAR PD #2394311 · Bathroom/Utility Room · Qualified 2022-04-01
Verified Specification Summary

The Fantech PB 270L10V2 (44947) (PB 270 Series) moves 260 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 3.9 CFM/W efficacy, sizing bathrooms up to 260 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech PB 270L10V2 (44947) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
260 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
0.1" test only
Motor Draw
66.7 W (24.3 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech PB 270L10V2 (44947) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech PB 270L10V2 (44947) (EPA filing PD #2394311) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Free-discharge delivery reaches 260 CFM (#28 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU PB 270L10V2 (44947) (series: PB 270 Series) (PD #2394311) certified since 2022-04-01. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 66.7 watts, about 24.3 kWh/yr (~$3.89/yr at $0.16/kWh) for 1 hr/day shower timers or 584.3 kWh/yr (~$93.49/yr) continuously. Closest competing matches include Dayton 5AE72A (240.0 CFM) and Greenheck SP-A200 (240.0 CFM).

How does duct geometry alter Fantech PB 270L10V2 (44947) static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Fantech PB 270L10V2 (44947)?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Fantech PB 270L10V2 (44947) alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series PB 270L10V2 (44947) / PB 270 Series PD ID 2394311 (Qualified 2022-04-01)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (260 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Fantech PB 270L10V2 (44947) ventilate safely?

Sizing outputs below convert Fantech PB 270L10V2 (44947) tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Fantech PB 270L10V2 (44947)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 260 sq ft1 CFM/sq ft @ 260 CFM
Tall Bath (9-ft Ceiling)Up to 231 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 210 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)24.3 kWh/yr (~$3.89/yr)66.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2584.3 kWh/yr (~$93.49/yr)66.7 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Fantech PB 270L10V2 (44947) closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 5AE72A 240 / N/A CFM 1.4 sones 4.3 CFM/W 8 x 8 in. rectangular
Greenheck SP-A200 240 / 224 CFM 1.4 sones 4.3 CFM/W 8 x 8 in. rectangular
S&P TD-150 260 / N/A CFM Unpublished 4.3 CFM/W 6 in. diameter
Broan L300EL 270 / N/A CFM Unpublished 3.9 CFM/W 8 in. diameter
S&P TD-150S 270 / N/A CFM Unpublished 4.5 CFM/W 6 in. diameter

Will Fantech PB 270L10V2 (44947) clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Fantech PB 270L10V2 (44947) satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Fantech PB 270L10V2 (44947) fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech PB 270L10V2 (44947).

Limitations & Who Should Skip

  • Steam or walk-in tub room > 210 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 260 sq ft with 8-ft ceilings (231 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern Fantech PB 270L10V2 (44947)?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Fantech PB 270L10V2 (44947).

Does running Fantech PB 270L10V2 (44947) continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Fantech PB 270L10V2 (44947) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Fantech PB 270L10V2 (44947) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech PB 270L10V2 (44947)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech PB 270L10V2 (44947)?

Fantech PB 270L10V2 (44947) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech PB 270L10V2 (44947)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech PB 270L10V2 (44947)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Is Fantech PB 270L10V2 (44947) code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech PB 270L10V2 (44947) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Fantech PB 270L10V2 (44947)?

Do not force Fantech PB 270L10V2 (44947) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Fantech PB 270L10V2 (44947) retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Fantech PB 270L10V2 (44947) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will Fantech PB 270L10V2 (44947) disturb adjacent bedrooms during night use?

Acoustic measurement places Fantech PB 270L10V2 (44947) at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories