Dayton 3DPE6A Exhaust Fan Specifications

ENERGY STAR PD #2335081 · Bathroom/Utility Room · Qualified 2015-10-15
Verified Specification Summary

The Dayton 3DPE6A (3DPE6A) moves 270 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), registers #604 of 607 in quietness (2.2 sones), and delivers 4.3 CFM/W efficacy, sizing bathrooms up to 270 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 3DPE6A Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
270 / N/A CFM
Noise @ 0.1"
2.2 sones (#604/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
0.1" test only
Motor Draw
62.8 W (22.9 kWh/yr)
Duct & Tier
8 x 8 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Dayton 3DPE6A vs. 1,145-Model ENERGY STAR Benchmarks show?

Utility-grade 2.2 sones acoustic output (#604 of 607 rated models, 1.20 sones louder than the 1.00 sones median), best reserved for powder rooms or laundry alcoves.

Free-discharge delivery reaches 270 CFM (#23 of 1,145 certified models) via a 8 x 8 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 8 x 8 in. rectangular housing before entering attic bays.

Dayton maintains 12 active ENERGY STAR blowers; 3DPE6A (series: 3DPE6A) (PD #2335081) gained qualification on 2015-10-15. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 62.8 watts, about 22.9 kWh/yr (~$3.66/yr at $0.16/kWh) for 1 hr/day shower timers or 550.1 kWh/yr (~$88.02/yr) continuously. Closest competing matches include Greenheck SP-A250 (270.0 CFM) and S&P TD-150S (270.0 CFM).

Where does Dayton 3DPE6A sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.2 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.2 sone: 2.2 sones (100th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.2 sone: 2.2 sones (P100)

How does duct geometry alter Dayton 3DPE6A static pressure?

Smooth 8 x 8 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Dayton 3DPE6A?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Dayton 3DPE6A alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Dayton (12 models) ENERGY STAR Certified Partner
Model Number & Series 3DPE6A / 3DPE6A PD ID 2335081 (Qualified 2015-10-15)
Duct Connection 8 x 8 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (270 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.2 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Dayton 3DPE6A ventilate safely?

Sizing outputs below convert Dayton 3DPE6A tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Dayton 3DPE6A
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 270 sq ft1 CFM/sq ft @ 270 CFM
Tall Bath (9-ft Ceiling)Up to 240 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 220 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)22.9 kWh/yr (~$3.66/yr)62.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2550.1 kWh/yr (~$88.02/yr)62.8 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Dayton 3DPE6A closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Greenheck SP-A250 270 / 250 CFM 2.2 sones (Same) 4.3 CFM/W 8 x 8 in. rectangular
S&P TD-150S 270 / N/A CFM Unpublished 4.5 CFM/W 6 in. diameter
Broan L250E 270 / 245 CFM Unpublished 4.6 CFM/W 8 in. diameter
Broan L300EL 270 / N/A CFM Unpublished 3.9 CFM/W 8 in. diameter
Fantech FR 150 (411334) 280 / N/A CFM Unpublished 4.3 CFM/W 6 in. diameter

Will Dayton 3DPE6A clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Dayton 3DPE6A satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

What plumbing or duct constraints rule out Dayton 3DPE6A?

Compare where Dayton 3DPE6A excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 220 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 270 sq ft with 8-ft ceilings (240 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 8 x 8 in. rectangular

What key rules and numbers govern Dayton 3DPE6A?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Dayton 3DPE6A.

Can Dayton 3DPE6A serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Dayton 3DPE6A supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Dayton 3DPE6A for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Dayton 3DPE6A lacks adequate reserve.

How does Dayton 3DPE6A handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Dayton 3DPE6A yields unlisted 0.25 in. w.g. backpressure figures, so smooth 8 x 8 in. rectangular rigid metal ducting protects real exhaust.

Is Dayton 3DPE6A quiet enough for a primary bedroom bathroom?

At 2.2 sones, Dayton 3DPE6A produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Dayton 3DPE6A energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Dayton 3DPE6A pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 3DPE6A's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Dayton 3DPE6A?

Dayton 3DPE6A features a 8 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Dayton 3DPE6A's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 3DPE6A's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)