Homeowners specifying Greenheck SP-A250 gain 270 CFM at 0.1 in. w.g. (250 CFM at 0.25 in. w.g.) where it registers #604 of 607 in quietness (2.2 sones) and delivers 4.3 CFM/W efficacy, venting bathrooms up to 250 sq ft cleanly through 8 x 8 in. rectangular rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A250 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 270 / 250 CFM
- Noise @ 0.1"
- 2.2 sones (#604/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 92.6% @ 0.25"
- Motor Draw
- 62.8 W (22.9 kWh/yr)
- Duct & Tier
- 8 x 8 in. rectangular · Standard

What does Greenheck SP-A250 vs. 1,145-Model ENERGY STAR Benchmarks show?
Utility-grade 2.2 sones acoustic output (#604 of 607 rated models, 1.20 sones louder than the 1.00 sones median), best reserved for powder rooms or laundry alcoves.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 250 CFM out of 270 CFM (92.6% retention, 4.9 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 8 x 8 in. rectangular housing before entering attic bays.
Greenheck maintains 31 active ENERGY STAR blowers; SP-A250 (series: SP) (PD #2335076) gained qualification on 2015-10-15. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 62.8 watts, about 22.9 kWh/yr (~$3.66/yr at $0.16/kWh) for 1 hr/day shower timers or 550.1 kWh/yr (~$88.02/yr) continuously. Closest competing matches include Dayton 3DPE6A (270.0 CFM) and S&P TD-150S (270.0 CFM).
What acoustic percentile does Greenheck SP-A250 occupy among 1,145 bath blowers?
Inspect how Greenheck SP-A250 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Greenheck SP-A250 best?
Exterior roof or wall damper termination paired with insulated 8 x 8 in. rectangular metal pipe prevents condensation buildup around Greenheck SP-A250 housings.
Where do Greenheck SP-A250 acoustic and static metrics stand?
Compare Greenheck SP-A250 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenheck (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-A250 / SP | PD ID 2335076 (Qualified 2015-10-15) |
| Duct Connection | 8 x 8 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (250 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Greenheck SP-A250 handle taller ceilings or walk-in tub steam?
Evaluate how Greenheck SP-A250 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 250 sq ft | 1 CFM/sq ft @ 250 CFM |
| Tall Bath (9-ft Ceiling) | Up to 222 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 200 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 22.9 kWh/yr (~$3.66/yr) | 62.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 550.1 kWh/yr (~$88.02/yr) | 62.8 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Greenheck SP-A250?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Dayton 3DPE6A | 270 / N/A CFM | 2.2 sones (Same) | 4.3 CFM/W | 8 x 8 in. rectangular |
| S&P TD-150S | 270 / N/A CFM | Unpublished | 4.5 CFM/W | 6 in. diameter |
| Broan L250E | 270 / 245 CFM | Unpublished | 4.6 CFM/W | 8 in. diameter |
| Broan L300EL | 270 / N/A CFM | Unpublished | 3.9 CFM/W | 8 in. diameter |
| Fantech FR 150 (411334) | 280 / N/A CFM | Unpublished | 4.3 CFM/W | 6 in. diameter |
Is Greenheck SP-A250 sized right for your shower or tub room?
Check whether Greenheck SP-A250 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
When does Greenheck SP-A250 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-A250.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 200 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 250 CFM net static output
- Target scenario: Collar pairs with 8 x 8 in. rectangular duct straight outdoors
Which code checks and cost facts matter for Greenheck SP-A250?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck SP-A250.
Does running Greenheck SP-A250 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-A250 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Greenheck SP-A250 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A250's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenheck SP-A250?
Greenheck SP-A250 features a 8 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenheck SP-A250's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A250's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Greenheck SP-A250 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A250 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Greenheck SP-A250?
Do not force Greenheck SP-A250 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Greenheck SP-A250 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-A250 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 8 x 8 in. rectangular metal duct transitions.
Will Greenheck SP-A250 disturb adjacent bedrooms during night use?
Acoustic measurement places Greenheck SP-A250 at 2.2 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)