Air King AK280LS Exhaust Fan Specifications

ENERGY STAR PD #2250892 · Bathroom/Utility Room · Qualified 2015-10-01
Verified Specification Summary

In EPA dataset 8dv7-nngq, Air King AK280LS tests at 280 CFM free discharge (257.1 CFM at 0.25 in. w.g.) and registers #607 of 607 in quietness (2.8 sones) and delivers 4.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 257 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK280LS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
280 / 257.1 CFM
Noise @ 0.1"
2.8 sones (#607/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
91.8% @ 0.25"
Motor Draw
65.1 W (23.8 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King AK280LS vs. 1,145-Model ENERGY STAR Benchmarks show?

Utility-grade 2.8 sones acoustic output (#607 of 607 rated models, 1.80 sones louder than the 1.00 sones median), best reserved for powder rooms or laundry alcoves.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 257.1 CFM out of 280 CFM (91.8% retention, 4.1 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Air King maintains 62 active ENERGY STAR blowers; AK280LS (series: N/A) (PD #2250892) gained qualification on 2015-10-01. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 65.1 watts, about 23.8 kWh/yr (~$3.81/yr at $0.16/kWh) for 1 hr/day shower timers or 570.3 kWh/yr (~$91.25/yr) continuously. Closest competing matches include Dayton 3DPE6A (270.0 CFM) and Greenheck SP-A250 (270.0 CFM).

Does Air King AK280LS fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Air King AK280LS at 2.8 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.8 sone: 2.8 sones (100th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.8 sone: 2.8 sones (P100)

Why avoid unvented attic termination with Air King AK280LS?

Under ASHRAE 62.2 best practice, Air King AK280LS needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Air King AK280LS?

Before cutting ceiling drywall or sizing attic transitions for Air King AK280LS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series AK280LS / N/A PD ID 2250892 (Qualified 2015-10-01)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (257.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Air King AK280LS?

Bathroom ventilation sizing below maps Air King AK280LS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Air King AK280LS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 257 sq ft1 CFM/sq ft @ 257.1 CFM
Tall Bath (9-ft Ceiling)Up to 228 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 207 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)23.8 kWh/yr (~$3.81/yr)65.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2570.3 kWh/yr (~$91.25/yr)65.1 W x 8,760 hrs / 1,000

What peer models sit nearest Air King AK280LS in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King AK280LS.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 3DPE6A 270 / N/A CFM 2.2 sones (-0.60) 4.3 CFM/W 8 x 8 in. rectangular
Greenheck SP-A250 270 / 250 CFM 2.2 sones (-0.60) 4.3 CFM/W 8 x 8 in. rectangular
Fantech FR 150 (411334) 280 / N/A CFM Unpublished 4.3 CFM/W 6 in. diameter
Panasonic FV-30VQ3 280 / 254.4 CFM 2.0 sones (-0.80) 4.4 CFM/W 6 in. diameter
S&P TD-150S 270 / N/A CFM Unpublished 4.5 CFM/W 6 in. diameter

What percentage of room demand does Air King AK280LS cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King AK280LS tested delivery.

Does Air King AK280LS suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Air King AK280LS for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 257.1 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 2.8 sones up to 257 sq ft
  • Best application: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Air King AK280LS?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King AK280LS.

Who should NOT install Air King AK280LS in a bathroom remodel?

Avoid specifying Air King AK280LS in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Air King AK280LS airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Air King AK280LS achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Air King AK280LS occupy in EPA filings?

With 2.8 sones at 0.1 in. w.g., Air King AK280LS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Air King AK280LS add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Air King AK280LS averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Air King AK280LS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK280LS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King AK280LS?

Air King AK280LS features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King AK280LS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK280LS's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Air King AK280LS pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Air King AK280LS easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)