Skip to main content
Grant Estimator

Dayton 5AE71 Exhaust Fan Specifications

ENERGY STAR PD #2366110 · Bathroom/Utility Room · Qualified 2015-10-15
Verified Specification Summary

Tested under HVI protocols, the Dayton 5AE71 exhaust unit achieves 210 CFM at 0.1 in. w.g. (186 CFM at 0.25 in. w.g.), registers #606 of 607 in quietness (2.4 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 186 sq ft on a 6 x 8 in. rectangular collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 5AE71 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
210 / 186 CFM
Noise @ 0.1"
2.4 sones (#606/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
88.6% @ 0.25"
Motor Draw
50.0 W (18.2 kWh/yr)
Duct & Tier
6 x 8 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Dayton 5AE71 vs. 1,145-Model ENERGY STAR Benchmarks show?

Utility-grade 2.4 sones acoustic output (#606 of 607 rated models, 1.40 sones louder than the 1.00 sones median), best reserved for powder rooms or laundry alcoves.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 186 CFM out of 210 CFM (88.6% retention, 0.9 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.

Inside Dayton's 12-unit lineup, 5AE71 (series: 5AE71) carries PD #2366110 dating to 2015-10-15. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 50.0 watts, about 18.2 kWh/yr (~$2.91/yr at $0.16/kWh) for 1 hr/day shower timers or 438.0 kWh/yr (~$70.08/yr) continuously. Closest competing matches include Greenheck CSP-A200 (213.0 CFM) and Broan L150E (210.0 CFM).

Where do Dayton 5AE71 sones rank across EPA ENERGY STAR fans?

Comparing Dayton 5AE71 (2.4 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 2.4 sone: 2.4 sones (100th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 2.4 sone: 2.4 sones (P100)

What attic duct routing preserves Dayton 5AE71 CFM output?

Short straight 6 x 8 in. rectangular duct paths retain up to ~82% of open-air capacity on Dayton 5AE71, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Dayton 5AE71 measure up on airflow and noise ratings?

Each row below breaks down Dayton 5AE71 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Dayton (12 models) ENERGY STAR Certified Partner
Model Number & Series 5AE71 / 5AE71 PD ID 2366110 (Qualified 2015-10-15)
Duct Connection 6 x 8 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (186 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (2.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Dayton 5AE71 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Dayton 5AE71
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 186 sq ft1 CFM/sq ft @ 186 CFM
Tall Bath (9-ft Ceiling)Up to 165 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 136 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)18.2 kWh/yr (~$2.91/yr)50.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2438.0 kWh/yr (~$70.08/yr)50.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Dayton 5AE71?

Compare Dayton 5AE71 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Greenheck CSP-A200 213 / 204 CFM Unpublished 3.9 CFM/W 8 x 6 in. rectangular
Broan L150E 210 / 175.2 CFM Unpublished 5.0 CFM/W 8 in. diameter
Broan L200EL 200 / N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200HT-P 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter

Can you size Dayton 5AE71 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Dayton 5AE71 verified capacity.

Does Dayton 5AE71 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Dayton 5AE71 for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 186 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 2.4 sones up to 186 sq ft
  • Best application: Paired with rigid galvanized 6 x 8 in. rectangular transition

How do federal and code standards apply to Dayton 5AE71?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Dayton 5AE71.

Who should NOT install Dayton 5AE71 in a bathroom remodel?

Avoid specifying Dayton 5AE71 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Dayton 5AE71 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Dayton 5AE71 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 x 8 in. rectangular smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Dayton 5AE71 occupy in EPA filings?

With 2.4 sones at 0.1 in. w.g., Dayton 5AE71 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Dayton 5AE71 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Dayton 5AE71 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Dayton 5AE71 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 5AE71's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Dayton 5AE71?

Dayton 5AE71 features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Dayton 5AE71's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 5AE71's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Dayton 5AE71 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Dayton 5AE71 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories