In EPA dataset 8dv7-nngq, Broan L150E tests at 210 CFM free discharge (175.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 5.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 175 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan L150E Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 210 / 175.2 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.0 CFM/W (#514/1,145)
- Static Retention
- 83.4% @ 0.25"
- Motor Draw
- 42.0 W (15.3 kWh/yr)
- Duct & Tier
- 8 in. diameter · Standard

What does Broan L150E vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan L150E (EPA filing PD #2405556) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 210 CFM open-air to 175.2 CFM at 0.25 in. w.g. (83.4% retention, 4.3 pts lower retention than the 87.7% median), making smooth 8 in. diameter rigid metal runs critical. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Broan maintains 207 active ENERGY STAR blowers; L150E (series: LIGHT COMMERCIAL) (PD #2405556) gained qualification on 2022-12-09. Lighting kit: No. At 5.0 CFM/W (#514 of 1,145, top 45.2% of 1,145 rated models, more efficient than 54.8% of rated models, 0.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 42.0 watts, about 15.3 kWh/yr (~$2.45/yr at $0.16/kWh) for 1 hr/day shower timers or 367.9 kWh/yr (~$58.86/yr) continuously. Closest competing matches include Dayton 6WZN6 (213.0 CFM) and Greenheck CSP-A200 (213.0 CFM).
Why avoid unvented attic termination with Broan L150E?
Under ASHRAE 62.2 best practice, Broan L150E needs insulated 8 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Broan L150E?
Before cutting ceiling drywall or sizing attic transitions for Broan L150E, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | L150E / LIGHT COMMERCIAL | PD ID 2405556 (Qualified 2022-12-09) |
| Duct Connection | 8 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (175.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Broan L150E?
Bathroom ventilation sizing below maps Broan L150E motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 175 sq ft | 1 CFM/sq ft @ 175.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 155 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 125 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 15.3 kWh/yr (~$2.45/yr) | 42.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 367.9 kWh/yr (~$58.86/yr) | 42.0 W x 8,760 hrs / 1,000 |
What peer models sit nearest Broan L150E in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan L150E.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Dayton 6WZN6 | 213 / 204 CFM | Unpublished | 3.9 CFM/W | 8 x 8 in. rectangular |
| Greenheck CSP-A200 | 213 / 204 CFM | Unpublished | 3.9 CFM/W | 8 x 6 in. rectangular |
| Delta VDBFRS200HT | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDBFRS200HT-P | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDBFRS200 | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
What percentage of room demand does Broan L150E cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan L150E tested delivery.
Where should contractors skip Broan L150E on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan L150E carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 175.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 175 sq ft
- Works well for: Paired with rigid galvanized 8 in. diameter transition
Where do official rules set limits for Broan L150E?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan L150E.
What duct and room conditions disqualify Broan L150E?
Rule out Broan L150E when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Broan L150E capacity?
Because static drag at 0.25 in. w.g. lowers Broan L150E from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 8 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Broan L150E compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Broan L150E produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Broan L150E consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan L150E draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan L150E pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan L150E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan L150E?
Broan L150E features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan L150E's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan L150E's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan L150E score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan L150E delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)