Tested under HVI protocols, the Delta SMT150-200 exhaust unit achieves 200 CFM at 0.1 in. w.g. (203.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 8.7 CFM/W efficacy, covering standard baths up to 203 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SMT150-200 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 200 / 203.4 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.7 CFM/W (#306/1,145)
- Static Retention
- 101.7% @ 0.25"
- Motor Draw
- 23.0 W (8.4 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Delta SMT150-200 vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta SMT150-200 (EPA filing PD #2384055) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 203.4 CFM out of 200 CFM (101.7% retention, 14.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms Delta SMT150-200 (series: BreezSmart) under PD #2384055 (121 models registered, 2021-08-13). Lighting kit: No. At 8.7 CFM/W (#306 of 1,145, top 27.6% of 1,145 rated models, more efficient than 72.4% of rated models, 4.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 23.0 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 201.5 kWh/yr (~$32.24/yr) continuously. Closest competing matches include Delta SMT150-200LED (200.0 CFM) and Delta VDB200 (200.0 CFM).
What attic duct routing preserves Delta SMT150-200 CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Delta SMT150-200, preventing premature peeling paint and mold growth.
How does Delta SMT150-200 measure up on airflow and noise ratings?
Each row below breaks down Delta SMT150-200 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SMT150-200 / BreezSmart | PD ID 2384055 (Qualified 2021-08-13) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (203.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Delta SMT150-200 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 203 sq ft | 1 CFM/sq ft @ 203.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 180 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 153 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 23.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 201.5 kWh/yr (~$32.24/yr) | 23.0 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Delta SMT150-200?
Compare Delta SMT150-200 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta SMT150-200LED | 200 / 204.9 CFM | Unpublished | 10.3 CFM/W | 6 in. diameter |
| Delta VDB200 | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| Broan FIN-180B | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |
| Broan FIN-180B-HW | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |
| Fantech FreshFlow(579865) | 200 / N/A CFM | Unpublished | 5.4 CFM/W | 6 in. diameter |
Can you size Delta SMT150-200 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta SMT150-200 verified capacity.
Does Delta SMT150-200 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta SMT150-200 for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 203.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around ENERGY STAR sones up to 203 sq ft
- Best application: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Delta SMT150-200?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta SMT150-200.
Does duct resistance cut Delta SMT150-200 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta SMT150-200 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Delta SMT150-200 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Delta SMT150-200 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Delta SMT150-200 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Delta SMT150-200 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Delta SMT150-200 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SMT150-200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SMT150-200?
Delta SMT150-200 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SMT150-200's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SMT150-200's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Delta SMT150-200 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta SMT150-200 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Delta SMT150-200 in a bathroom remodel?
Avoid specifying Delta SMT150-200 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)