Skip to main content
Grant Estimator

Delta SMT150-200 Exhaust Fan Specifications

ENERGY STAR PD #2384055 · Bathroom/Utility Room · Qualified 2021-08-13
Verified Specification Summary

Tested under HVI protocols, the Delta SMT150-200 exhaust unit achieves 200 CFM at 0.1 in. w.g. (203.4 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 8.7 CFM/W efficacy, covering standard baths up to 203 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SMT150-200 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
200 / 203.4 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.7 CFM/W (#306/1,145)
Static Retention
101.7% @ 0.25"
Motor Draw
23.0 W (8.4 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SMT150-200 vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SMT150-200 (EPA filing PD #2384055) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 203.4 CFM out of 200 CFM (101.7% retention, 14.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Delta SMT150-200 (series: BreezSmart) under PD #2384055 (121 models registered, 2021-08-13). Lighting kit: No. At 8.7 CFM/W (#306 of 1,145, top 27.6% of 1,145 rated models, more efficient than 72.4% of rated models, 4.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 23.0 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 201.5 kWh/yr (~$32.24/yr) continuously. Closest competing matches include Delta SMT150-200LED (200.0 CFM) and Delta VDB200 (200.0 CFM).

What attic duct routing preserves Delta SMT150-200 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Delta SMT150-200, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Delta SMT150-200 measure up on airflow and noise ratings?

Each row below breaks down Delta SMT150-200 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SMT150-200 / BreezSmart PD ID 2384055 (Qualified 2021-08-13)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (203.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Delta SMT150-200 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta SMT150-200
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 203 sq ft1 CFM/sq ft @ 203.4 CFM
Tall Bath (9-ft Ceiling)Up to 180 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 153 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.4 kWh/yr (~$1.34/yr)23.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2201.5 kWh/yr (~$32.24/yr)23.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Delta SMT150-200?

Compare Delta SMT150-200 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta SMT150-200LED 200 / 204.9 CFM Unpublished 10.3 CFM/W 6 in. diameter
Delta VDB200 200 / N/A CFM Unpublished 6.6 CFM/W 6 in. diameter
Broan FIN-180B 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter
Broan FIN-180B-HW 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter
Fantech FreshFlow(579865) 200 / N/A CFM Unpublished 5.4 CFM/W 6 in. diameter

Can you size Delta SMT150-200 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta SMT150-200 verified capacity.

Does Delta SMT150-200 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta SMT150-200 for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 203.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around ENERGY STAR sones up to 203 sq ft
  • Best application: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Delta SMT150-200?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta SMT150-200.

Does duct resistance cut Delta SMT150-200 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta SMT150-200 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Delta SMT150-200 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Delta SMT150-200 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Delta SMT150-200 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Delta SMT150-200 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Delta SMT150-200 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SMT150-200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SMT150-200?

Delta SMT150-200 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SMT150-200's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SMT150-200's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Delta SMT150-200 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta SMT150-200 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Delta SMT150-200 in a bathroom remodel?

Avoid specifying Delta SMT150-200 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories