Rated for 180 CFM open-air (unpublished 0.25 in. w.g. output), Broan FIN-180B omits a published 0.1-inch sone rating and delivers 6.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 180 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan FIN-180B Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 180 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 6.8 CFM/W (#429/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 26.5 W (9.7 kWh/yr)
- Duct & Tier
- 6 in. diameter · Most Eff.

What does Broan FIN-180B vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan FIN-180B (EPA filing PD #2343240) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 180 CFM (#69 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Broan registers 207 certified models, with SKU FIN-180B (series: FIN180B) (PD #2343240) certified since 2018-09-28. Lighting kit: No. At 6.8 CFM/W (#429 of 1,145, top 37.6% of 1,145 rated models, more efficient than 62.4% of rated models, 2.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 26.5 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 232.1 kWh/yr (~$37.14/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Ortech OIF5-190 (180.0 CFM).
How do flex elbows choke Broan FIN-180B at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan FIN-180B moving full rated CFM.
Does Broan FIN-180B meet residential exhaust fan code specs?
Inspect Broan FIN-180B mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FIN-180B / FIN180B | PD ID 2343240 (Qualified 2018-09-28) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (180 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan FIN-180B airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan FIN-180B tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 180 sq ft | 1 CFM/sq ft @ 180 CFM |
| Tall Bath (9-ft Ceiling) | Up to 160 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 130 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 232.1 kWh/yr (~$37.14/yr) | 26.5 W x 8,760 hrs / 1,000 |
Which competing models share Broan FIN-180B airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Ortech OIF5-190 | 180 / N/A CFM | Unpublished | 4.9 CFM/W | 5 in. diameter |
| S&P RF10-160EC | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| S&P RF10-160EC-ES24V | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| S&P RF10-160EC-P | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
How much airflow margin does Broan FIN-180B give your bath?
Run a quick local room-volume check for Broan FIN-180B by entering square footage and ceiling height to spot under-vented steam risks early.
Who should not install Broan FIN-180B in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan FIN-180B for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 130 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 180 sq ft with 8-ft ceilings (160 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Broan FIN-180B?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan FIN-180B.
What electrical efficiency and runtime kWh define Broan FIN-180B?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Broan FIN-180B pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan FIN-180B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan FIN-180B?
Broan FIN-180B features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan FIN-180B's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan FIN-180B's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan FIN-180B satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan FIN-180B clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Broan FIN-180B undersized or poorly matched for a bath renovation?
Skip Broan FIN-180B if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Broan FIN-180B CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan FIN-180B registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does Broan FIN-180B sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Broan FIN-180B produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)