Certified by EPA ENERGY STAR, Broan FIN-180B-HW delivers 180 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 6.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 180 sq ft (8-ft height) or 160 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan FIN-180B-HW Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 180 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 6.8 CFM/W (#429/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 26.5 W (9.7 kWh/yr)
- Duct & Tier
- 6 in. diameter · Most Eff.

What does Broan FIN-180B-HW vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan FIN-180B-HW (EPA filing PD #2401613) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 180 CFM (#69 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #2401613 verifies FIN-180B-HW (series: FIN-180) under Broan (207 listed models, qualified 2022-09-16). Lighting kit: No. At 6.8 CFM/W (#429 of 1,145, top 37.6% of 1,145 rated models, more efficient than 62.4% of rated models, 2.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 26.5 watts, about 9.7 kWh/yr (~$1.55/yr at $0.16/kWh) for 1 hr/day shower timers or 232.1 kWh/yr (~$37.14/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Ortech OIF5-190 (180.0 CFM).
Why does rigid 6 in. diameter ducting protect Broan FIN-180B-HW airflow?
Connecting Broan FIN-180B-HW through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan FIN-180B-HW performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan FIN-180B-HW lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FIN-180B-HW / FIN-180 | PD ID 2401613 (Qualified 2022-09-16) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (180 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan FIN-180B-HW?
Calculated coverage metrics translate Broan FIN-180B-HW airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 180 sq ft | 1 CFM/sq ft @ 180 CFM |
| Tall Bath (9-ft Ceiling) | Up to 160 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 130 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.7 kWh/yr (~$1.55/yr) | 26.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 232.1 kWh/yr (~$37.14/yr) | 26.5 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan FIN-180B-HW?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Ortech OIF5-190 | 180 / N/A CFM | Unpublished | 4.9 CFM/W | 5 in. diameter |
| S&P RF10-160EC | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| S&P RF10-160EC-ES24V | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| S&P RF10-160EC-P | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
Does Broan FIN-180B-HW match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan FIN-180B-HW percentage capacity without sending data.
What plumbing or duct constraints rule out Broan FIN-180B-HW?
Compare where Broan FIN-180B-HW excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 130 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 180 CFM net static output
- Suited to: Collar pairs with 6 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan FIN-180B-HW?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan FIN-180B-HW.
How does Broan FIN-180B-HW handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan FIN-180B-HW yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is Broan FIN-180B-HW quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Broan FIN-180B-HW produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Broan FIN-180B-HW energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Broan FIN-180B-HW pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan FIN-180B-HW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan FIN-180B-HW?
Broan FIN-180B-HW features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan FIN-180B-HW's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan FIN-180B-HW's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Broan FIN-180B-HW serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Broan FIN-180B-HW supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Broan FIN-180B-HW for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan FIN-180B-HW lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)