Ortech OIF5-190 Exhaust Fan Specifications

ENERGY STAR PD #3999565 · In-line (single-port) · Qualified 2025-03-07
Verified Specification Summary

In EPA dataset 8dv7-nngq, Ortech OIF5-190 tests at 180 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 180 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OIF5-190 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
180 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.9 CFM/W (#519/1,145)
Static Retention
0.1" test only
Motor Draw
36.7 W (13.4 kWh/yr)
Duct & Tier
5 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech OIF5-190 vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech OIF5-190 (EPA filing PD #3999565) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 180 CFM (#69 of 1,145 certified models) via a 5 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places OIF5-190 (series: Inline fan 5inch) (PD #3999565) among 27 Ortech entries qualified through 2025-03-07. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 36.7 watts, about 13.4 kWh/yr (~$2.14/yr at $0.16/kWh) for 1 hr/day shower timers or 321.5 kWh/yr (~$51.44/yr) continuously. Closest competing matches include Broan ALT4306SS (160.0 CFM) and S&P RF10-160EC (170.0 CFM).

Why avoid unvented attic termination with Ortech OIF5-190?

Under ASHRAE 62.2 best practice, Ortech OIF5-190 needs insulated 5 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Ortech OIF5-190?

Before cutting ceiling drywall or sizing attic transitions for Ortech OIF5-190, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series OIF5-190 / Inline fan 5inch PD ID 3999565 (Qualified 2025-03-07)
Duct Connection 5 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (180 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Ortech OIF5-190?

Bathroom ventilation sizing below maps Ortech OIF5-190 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Ortech OIF5-190
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 180 sq ft1 CFM/sq ft @ 180 CFM
Tall Bath (9-ft Ceiling)Up to 160 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 130 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)13.4 kWh/yr (~$2.14/yr)36.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2321.5 kWh/yr (~$51.44/yr)36.7 W x 8,760 hrs / 1,000

What peer models sit nearest Ortech OIF5-190 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Ortech OIF5-190.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
S&P RF10-160EC 170 / N/A CFM Unpublished 5.2 CFM/W 6 in. diameter
S&P RF10-160EC-ES24V 170 / N/A CFM Unpublished 5.2 CFM/W 6 in. diameter
S&P RF10-160EC-P 170 / N/A CFM Unpublished 5.2 CFM/W 6 in. diameter
S&P RF10-160EC-P-ES24V 170 / N/A CFM Unpublished 5.2 CFM/W 6 in. diameter

What percentage of room demand does Ortech OIF5-190 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Ortech OIF5-190 tested delivery.

When does Ortech OIF5-190 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Ortech OIF5-190.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 180 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 180 sq ft
  • Target scenario: Paired with rigid galvanized 5 in. diameter transition

Where do official rules set limits for Ortech OIF5-190?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Ortech OIF5-190.

Does running Ortech OIF5-190 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Ortech OIF5-190 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Ortech OIF5-190 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OIF5-190's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech OIF5-190?

Ortech OIF5-190 features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech OIF5-190's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OIF5-190's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Ortech OIF5-190 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Ortech OIF5-190 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Ortech OIF5-190?

Do not force Ortech OIF5-190 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Ortech OIF5-190 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Ortech OIF5-190 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 5 in. diameter metal duct transitions.

Will Ortech OIF5-190 disturb adjacent bedrooms during night use?

Acoustic measurement places Ortech OIF5-190 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.