Homeowners specifying Broan FIN-180P-HW gain 180 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it omits a published 0.1-inch sone rating and delivers 6.4 CFM/W efficacy, venting bathrooms up to 180 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan FIN-180P-HW Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 180 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 6.4 CFM/W (#438/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 28.1 W (10.3 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan FIN-180P-HW vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan FIN-180P-HW (EPA filing PD #2401612) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 180 CFM (#69 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #2401612 verifies FIN-180P-HW (series: FIN-180) under Broan (207 listed models, qualified 2022-09-16). Lighting kit: No. At 6.4 CFM/W (#438 of 1,145, top 38.8% of 1,145 rated models, more efficient than 61.2% of rated models, 1.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 28.1 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 246.2 kWh/yr (~$39.39/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and Ortech OIF5-190 (180.0 CFM).
Which exterior damper path suits Broan FIN-180P-HW best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Broan FIN-180P-HW housings.
Where do Broan FIN-180P-HW acoustic and static metrics stand?
Compare Broan FIN-180P-HW published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FIN-180P-HW / FIN-180 | PD ID 2401612 (Qualified 2022-09-16) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (180 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Broan FIN-180P-HW handle taller ceilings or walk-in tub steam?
Evaluate how Broan FIN-180P-HW scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 180 sq ft | 1 CFM/sq ft @ 180 CFM |
| Tall Bath (9-ft Ceiling) | Up to 160 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 130 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 246.2 kWh/yr (~$39.39/yr) | 28.1 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Broan FIN-180P-HW?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Ortech OIF5-190 | 180 / N/A CFM | Unpublished | 4.9 CFM/W | 5 in. diameter |
| S&P RF10-160EC | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| S&P RF10-160EC-ES24V | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| S&P RF10-160EC-P | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
Is Broan FIN-180P-HW sized right for your shower or tub room?
Check whether Broan FIN-180P-HW clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
When does Broan FIN-180P-HW fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan FIN-180P-HW.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 130 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 180 CFM net static output
- Target scenario: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for Broan FIN-180P-HW?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan FIN-180P-HW.
Will Broan FIN-180P-HW disturb adjacent bedrooms during night use?
Acoustic measurement places Broan FIN-180P-HW at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan FIN-180P-HW continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan FIN-180P-HW draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan FIN-180P-HW pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan FIN-180P-HW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan FIN-180P-HW?
Broan FIN-180P-HW features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan FIN-180P-HW's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan FIN-180P-HW's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan FIN-180P-HW code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan FIN-180P-HW clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan FIN-180P-HW?
Do not force Broan FIN-180P-HW into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan FIN-180P-HW retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan FIN-180P-HW produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)