The Broan L150EL (LIGHT COMMERCIAL) moves 170 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 4.2 CFM/W efficacy, sizing bathrooms up to 170 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan L150EL Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 170 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 40.5 W (14.8 kWh/yr)
- Duct & Tier
- 8 in. diameter · Standard

What does Broan L150EL vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan L150EL (EPA filing PD #2405561) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 170 CFM (#77 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2405561 verifies L150EL (series: LIGHT COMMERCIAL) under Broan (207 listed models, qualified 2022-12-09). Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 40.5 watts, about 14.8 kWh/yr (~$2.37/yr at $0.16/kWh) for 1 hr/day shower timers or 354.8 kWh/yr (~$56.77/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Broan ALT4306SS (160.0 CFM).
How does duct geometry alter Broan L150EL static pressure?
Smooth 8 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan L150EL?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan L150EL alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | L150EL / LIGHT COMMERCIAL | PD ID 2405561 (Qualified 2022-12-09) |
| Duct Connection | 8 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (170 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Broan L150EL ventilate safely?
Sizing outputs below convert Broan L150EL tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 170 sq ft | 1 CFM/sq ft @ 170 CFM |
| Tall Bath (9-ft Ceiling) | Up to 151 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 120 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 14.8 kWh/yr (~$2.37/yr) | 40.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 354.8 kWh/yr (~$56.77/yr) | 40.5 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan L150EL closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| S&P RF10-160EC | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
| S&P RF10-160EC-ES24V | 170 / N/A CFM | Unpublished | 5.2 CFM/W | 6 in. diameter |
Will Broan L150EL clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan L150EL satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does Broan L150EL suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan L150EL for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 120 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 170 sq ft with 8-ft ceilings (151 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 8 in. diameter
What key rules and numbers govern Broan L150EL?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan L150EL.
How many kWh per year does Broan L150EL add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan L150EL averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan L150EL pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan L150EL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan L150EL?
Broan L150EL features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan L150EL's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan L150EL's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan L150EL pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan L150EL easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan L150EL in a bathroom remodel?
Avoid specifying Broan L150EL in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan L150EL airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan L150EL achieves unlisted 0.25 in. w.g. backpressure figures; matching a 8 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Broan L150EL occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan L150EL produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)