S&P RF10-160EC Exhaust Fan Specifications

ENERGY STAR PD #2343217 · In-line (single-port) · Qualified 2018-04-27
Verified Specification Summary

The S&P RF10-160EC (Refresh) moves 170 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 5.2 CFM/W efficacy, sizing bathrooms up to 170 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P RF10-160EC Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
170 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.2 CFM/W (#499/1,145)
Static Retention
0.1" test only
Motor Draw
32.7 W (11.9 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P RF10-160EC vs. 1,145-Model ENERGY STAR Benchmarks show?

S&P RF10-160EC (EPA filing PD #2343217) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 170 CFM (#77 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside S&P's 29-unit lineup, RF10-160EC (series: Refresh) carries PD #2343217 dating to 2018-04-27. Lighting kit: No. At 5.2 CFM/W (#499 of 1,145, top 44.2% of 1,145 rated models, more efficient than 55.8% of rated models, 0.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 32.7 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 286.5 kWh/yr (~$45.84/yr) continuously. Closest competing matches include Broan ALT4306SS (160.0 CFM) and Broan QT150LE (150.0 CFM).

How does duct geometry alter S&P RF10-160EC static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to S&P RF10-160EC?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for S&P RF10-160EC alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series RF10-160EC / Refresh PD ID 2343217 (Qualified 2018-04-27)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (170 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can S&P RF10-160EC ventilate safely?

Sizing outputs below convert S&P RF10-160EC tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for S&P RF10-160EC
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 170 sq ft1 CFM/sq ft @ 170 CFM
Tall Bath (9-ft Ceiling)Up to 151 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 120 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.9 kWh/yr (~$1.90/yr)32.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2286.5 kWh/yr (~$45.84/yr)32.7 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match S&P RF10-160EC closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
KORA SBF160DC-MS 161.6 / N/A CFM 1.3 sones 8.7 CFM/W 4 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular

Will S&P RF10-160EC clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether S&P RF10-160EC satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Who should not install S&P RF10-160EC in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting S&P RF10-160EC for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 120 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 170 sq ft with 8-ft ceilings (151 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern S&P RF10-160EC?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting S&P RF10-160EC.

What electrical efficiency and runtime kWh define S&P RF10-160EC?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can S&P RF10-160EC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P RF10-160EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P RF10-160EC?

S&P RF10-160EC features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P RF10-160EC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P RF10-160EC's safe coverage footprint from 50 sq ft to 44 sq ft.

Does S&P RF10-160EC satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), S&P RF10-160EC clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is S&P RF10-160EC undersized or poorly matched for a bath renovation?

Skip S&P RF10-160EC if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check S&P RF10-160EC CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, S&P RF10-160EC registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

How does S&P RF10-160EC sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, S&P RF10-160EC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories