S&P RF10-160EC-P-ES24V Exhaust Fan Specifications

ENERGY STAR PD #2343209 · In-line (single-port) · Qualified 2018-04-27
Verified Specification Summary

Tested under HVI protocols, the S&P RF10-160EC-P-ES24V exhaust unit achieves 170 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 5.2 CFM/W efficacy, covering standard baths up to 170 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P RF10-160EC-P-ES24V Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
170 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.2 CFM/W (#499/1,145)
Static Retention
0.1" test only
Motor Draw
32.7 W (11.9 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P RF10-160EC-P-ES24V vs. 1,145-Model ENERGY STAR Benchmarks show?

S&P RF10-160EC-P-ES24V (EPA filing PD #2343209) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 170 CFM (#77 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: S&P registers 29 certified models, with SKU RF10-160EC-P-ES24V (series: Refresh) (PD #2343209) certified since 2018-04-27. Lighting kit: No. At 5.2 CFM/W (#499 of 1,145, top 44.2% of 1,145 rated models, more efficient than 55.8% of rated models, 0.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 32.7 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 286.5 kWh/yr (~$45.84/yr) continuously. Closest competing matches include Broan ALT4306SS (160.0 CFM) and Broan QT150LE (150.0 CFM).

What attic duct routing preserves S&P RF10-160EC-P-ES24V CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on S&P RF10-160EC-P-ES24V, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does S&P RF10-160EC-P-ES24V measure up on airflow and noise ratings?

Each row below breaks down S&P RF10-160EC-P-ES24V certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series RF10-160EC-P-ES24V / Refresh PD ID 2343209 (Qualified 2018-04-27)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (170 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect S&P RF10-160EC-P-ES24V CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for S&P RF10-160EC-P-ES24V
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 170 sq ft1 CFM/sq ft @ 170 CFM
Tall Bath (9-ft Ceiling)Up to 151 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 120 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.9 kWh/yr (~$1.90/yr)32.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2286.5 kWh/yr (~$45.84/yr)32.7 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against S&P RF10-160EC-P-ES24V?

Compare S&P RF10-160EC-P-ES24V side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
KORA SBF160DC-MS 161.6 / N/A CFM 1.3 sones 8.7 CFM/W 4 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular

Can you size S&P RF10-160EC-P-ES24V for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against S&P RF10-160EC-P-ES24V verified capacity.

What plumbing or duct constraints rule out S&P RF10-160EC-P-ES24V?

Compare where S&P RF10-160EC-P-ES24V excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 170 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around ENERGY STAR sones up to 170 sq ft
  • Suited to: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to S&P RF10-160EC-P-ES24V?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for S&P RF10-160EC-P-ES24V.

Why might a contractor swap S&P RF10-160EC-P-ES24V for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, S&P RF10-160EC-P-ES24V lacks adequate reserve.

How does S&P RF10-160EC-P-ES24V handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., S&P RF10-160EC-P-ES24V yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is S&P RF10-160EC-P-ES24V quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, S&P RF10-160EC-P-ES24V produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is S&P RF10-160EC-P-ES24V energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can S&P RF10-160EC-P-ES24V pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P RF10-160EC-P-ES24V's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P RF10-160EC-P-ES24V?

S&P RF10-160EC-P-ES24V features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P RF10-160EC-P-ES24V's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P RF10-160EC-P-ES24V's safe coverage footprint from 50 sq ft to 44 sq ft.

Can S&P RF10-160EC-P-ES24V serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: S&P RF10-160EC-P-ES24V supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories