Tested under HVI protocols, the S&P RF10-160EC-P-ES24V exhaust unit achieves 170 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 5.2 CFM/W efficacy, covering standard baths up to 170 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P RF10-160EC-P-ES24V Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 170 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.2 CFM/W (#499/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 32.7 W (11.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does S&P RF10-160EC-P-ES24V vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P RF10-160EC-P-ES24V (EPA filing PD #2343209) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 170 CFM (#77 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: S&P registers 29 certified models, with SKU RF10-160EC-P-ES24V (series: Refresh) (PD #2343209) certified since 2018-04-27. Lighting kit: No. At 5.2 CFM/W (#499 of 1,145, top 44.2% of 1,145 rated models, more efficient than 55.8% of rated models, 0.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 32.7 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 286.5 kWh/yr (~$45.84/yr) continuously. Closest competing matches include Broan ALT4306SS (160.0 CFM) and Broan QT150LE (150.0 CFM).
What attic duct routing preserves S&P RF10-160EC-P-ES24V CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on S&P RF10-160EC-P-ES24V, preventing premature peeling paint and mold growth.
How does S&P RF10-160EC-P-ES24V measure up on airflow and noise ratings?
Each row below breaks down S&P RF10-160EC-P-ES24V certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RF10-160EC-P-ES24V / Refresh | PD ID 2343209 (Qualified 2018-04-27) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (170 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect S&P RF10-160EC-P-ES24V CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 170 sq ft | 1 CFM/sq ft @ 170 CFM |
| Tall Bath (9-ft Ceiling) | Up to 151 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 120 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 286.5 kWh/yr (~$45.84/yr) | 32.7 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against S&P RF10-160EC-P-ES24V?
Compare S&P RF10-160EC-P-ES24V side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones | 8.7 CFM/W | 4 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
Can you size S&P RF10-160EC-P-ES24V for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against S&P RF10-160EC-P-ES24V verified capacity.
What plumbing or duct constraints rule out S&P RF10-160EC-P-ES24V?
Compare where S&P RF10-160EC-P-ES24V excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 170 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 170 sq ft
- Suited to: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to S&P RF10-160EC-P-ES24V?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for S&P RF10-160EC-P-ES24V.
Why might a contractor swap S&P RF10-160EC-P-ES24V for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, S&P RF10-160EC-P-ES24V lacks adequate reserve.
How does S&P RF10-160EC-P-ES24V handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., S&P RF10-160EC-P-ES24V yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is S&P RF10-160EC-P-ES24V quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, S&P RF10-160EC-P-ES24V produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is S&P RF10-160EC-P-ES24V energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can S&P RF10-160EC-P-ES24V pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P RF10-160EC-P-ES24V's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P RF10-160EC-P-ES24V?
S&P RF10-160EC-P-ES24V features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P RF10-160EC-P-ES24V's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P RF10-160EC-P-ES24V's safe coverage footprint from 50 sq ft to 44 sq ft.
Can S&P RF10-160EC-P-ES24V serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: S&P RF10-160EC-P-ES24V supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)