In EPA dataset 8dv7-nngq, Delta VDBFRS200HT-P tests at 200 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 200 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta VDBFRS200HT-P Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 200 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.9 CFM/W (#519/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 40.8 W (14.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Most Eff.

What does Delta VDBFRS200HT-P vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta VDBFRS200HT-P (EPA filing PD #4577054) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Delta registers 121 certified models, with SKU VDBFRS200HT-P (series: BreezFresh) (PD #4577054) certified since 2026-03-25. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 40.8 watts, about 14.9 kWh/yr (~$2.38/yr at $0.16/kWh) for 1 hr/day shower timers or 357.4 kWh/yr (~$57.18/yr) continuously. Closest competing matches include Fantech FreshFlow(579865) (200.0 CFM) and Broan L200EL (200.0 CFM).
Why avoid unvented attic termination with Delta VDBFRS200HT-P?
Under ASHRAE 62.2 best practice, Delta VDBFRS200HT-P needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Delta VDBFRS200HT-P?
Before cutting ceiling drywall or sizing attic transitions for Delta VDBFRS200HT-P, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VDBFRS200HT-P / BreezFresh | PD ID 4577054 (Qualified 2026-03-25) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (200 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Delta VDBFRS200HT-P?
Bathroom ventilation sizing below maps Delta VDBFRS200HT-P motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 200 sq ft | 1 CFM/sq ft @ 200 CFM |
| Tall Bath (9-ft Ceiling) | Up to 177 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 150 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 14.9 kWh/yr (~$2.38/yr) | 40.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 357.4 kWh/yr (~$57.18/yr) | 40.8 W x 8,760 hrs / 1,000 |
What peer models sit nearest Delta VDBFRS200HT-P in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta VDBFRS200HT-P.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Fantech FreshFlow(579865) | 200 / N/A CFM | Unpublished | 5.4 CFM/W | 6 in. diameter |
| Broan L200EL | 200 / N/A CFM | Unpublished | 4.0 CFM/W | 8 in. diameter |
| Broan L150E | 210 / 175.2 CFM | Unpublished | 5.0 CFM/W | 8 in. diameter |
| Zephyr ZSI-E30BS-ES | 200 / N/A CFM | Unpublished | 3.5 CFM/W | 8 in. diameter |
| Zephyr ZSI-E36BS-ES | 200 / N/A CFM | Unpublished | 3.5 CFM/W | 8 in. diameter |
What percentage of room demand does Delta VDBFRS200HT-P cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta VDBFRS200HT-P tested delivery.
Where should contractors skip Delta VDBFRS200HT-P on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta VDBFRS200HT-P carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 200 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 200 sq ft
- Works well for: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Delta VDBFRS200HT-P?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta VDBFRS200HT-P.
How does Delta VDBFRS200HT-P score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta VDBFRS200HT-P delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Delta VDBFRS200HT-P?
Rule out Delta VDBFRS200HT-P when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Delta VDBFRS200HT-P capacity?
Because static drag at 0.25 in. w.g. lowers Delta VDBFRS200HT-P from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Delta VDBFRS200HT-P compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Delta VDBFRS200HT-P produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Delta VDBFRS200HT-P consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Delta VDBFRS200HT-P draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Delta VDBFRS200HT-P pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta VDBFRS200HT-P's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta VDBFRS200HT-P?
Delta VDBFRS200HT-P features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta VDBFRS200HT-P's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta VDBFRS200HT-P's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)