Homeowners specifying Fantech FreshFlow(579865) gain 200 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it omits a published 0.1-inch sone rating and delivers 5.4 CFM/W efficacy, venting bathrooms up to 200 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FreshFlow(579865) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 200 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.4 CFM/W (#491/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 37.0 W (13.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Fantech FreshFlow(579865) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech FreshFlow(579865) (EPA filing PD #4708500) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms Fantech FreshFlow(579865) (series: FreshFlow) under PD #4708500 (52 models registered, 2026-09-23). Lighting kit: No. At 5.4 CFM/W (#491 of 1,145, top 43.1% of 1,145 rated models, more efficient than 56.9% of rated models, 0.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 37.0 watts, about 13.5 kWh/yr (~$2.16/yr at $0.16/kWh) for 1 hr/day shower timers or 324.1 kWh/yr (~$51.86/yr) continuously. Closest competing matches include Delta VDBFRS200 (200.0 CFM) and Delta VDBFRS200HT (200.0 CFM).
Which exterior damper path suits Fantech FreshFlow(579865) best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Fantech FreshFlow(579865) housings.
Where do Fantech FreshFlow(579865) acoustic and static metrics stand?
Compare Fantech FreshFlow(579865) published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FreshFlow(579865) / FreshFlow | PD ID 4708500 (Qualified 2026-09-23) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (200 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Fantech FreshFlow(579865) handle taller ceilings or walk-in tub steam?
Evaluate how Fantech FreshFlow(579865) scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 200 sq ft | 1 CFM/sq ft @ 200 CFM |
| Tall Bath (9-ft Ceiling) | Up to 177 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 150 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 13.5 kWh/yr (~$2.16/yr) | 37.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 324.1 kWh/yr (~$51.86/yr) | 37.0 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Fantech FreshFlow(579865)?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta VDBFRS200 | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| Delta VDBFRS200HT | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDBFRS200HT-P | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDB200 | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| Broan L150E | 210 / 175.2 CFM | Unpublished | 5.0 CFM/W | 8 in. diameter |
Is Fantech FreshFlow(579865) sized right for your shower or tub room?
Check whether Fantech FreshFlow(579865) clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Which bath layouts should avoid specifying Fantech FreshFlow(579865)?
Match Fantech FreshFlow(579865) directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 150 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 200 CFM net static output
- Optimal use: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for Fantech FreshFlow(579865)?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Fantech FreshFlow(579865).
Where does Fantech FreshFlow(579865) run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Fantech FreshFlow(579865).
What happens to Fantech FreshFlow(579865) CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Fantech FreshFlow(579865) moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Fantech FreshFlow(579865) sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Fantech FreshFlow(579865) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Fantech FreshFlow(579865) cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Fantech FreshFlow(579865) 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Fantech FreshFlow(579865) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FreshFlow(579865)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech FreshFlow(579865)?
Fantech FreshFlow(579865) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech FreshFlow(579865)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FreshFlow(579865)'s safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Fantech FreshFlow(579865) ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Fantech FreshFlow(579865) covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)