Skip to main content
Grant Estimator

Delta VDB200 Exhaust Fan Specifications

ENERGY STAR PD #4528854 · In-line (single-port) · Qualified 2026-01-28
Verified Specification Summary

Tested under HVI protocols, the Delta VDB200 exhaust unit achieves 200 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 6.6 CFM/W efficacy, covering standard baths up to 200 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta VDB200 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
200 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
6.6 CFM/W (#433/1,145)
Static Retention
0.1" test only
Motor Draw
30.3 W (11.1 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta VDB200 vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta VDB200 (EPA filing PD #4528854) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Delta's 121-unit lineup, VDB200 (series: BreezFresh) carries PD #4528854 dating to 2026-01-28. Lighting kit: No. At 6.6 CFM/W (#433 of 1,145, top 38.0% of 1,145 rated models, more efficient than 62.0% of rated models, 1.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 30.3 watts, about 11.1 kWh/yr (~$1.78/yr at $0.16/kWh) for 1 hr/day shower timers or 265.4 kWh/yr (~$42.46/yr) continuously. Closest competing matches include Fantech FreshFlow(579865) (200.0 CFM) and Broan L150E (210.0 CFM).

What attic duct routing preserves Delta VDB200 CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Delta VDB200, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Delta VDB200 measure up on airflow and noise ratings?

Each row below breaks down Delta VDB200 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series VDB200 / BreezFresh PD ID 4528854 (Qualified 2026-01-28)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (200 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Delta VDB200 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta VDB200
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 200 sq ft1 CFM/sq ft @ 200 CFM
Tall Bath (9-ft Ceiling)Up to 177 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 150 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.1 kWh/yr (~$1.78/yr)30.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2265.4 kWh/yr (~$42.46/yr)30.3 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Delta VDB200?

Compare Delta VDB200 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Fantech FreshFlow(579865) 200 / N/A CFM Unpublished 5.4 CFM/W 6 in. diameter
Broan L150E 210 / 175.2 CFM Unpublished 5.0 CFM/W 8 in. diameter
Aprilaire 8145 190 / N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Aprilaire 8145NC 190 / N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Broan L200EL 200 / N/A CFM Unpublished 4.0 CFM/W 8 in. diameter

Can you size Delta VDB200 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta VDB200 verified capacity.

When does Delta VDB200 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta VDB200.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 200 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 200 sq ft
  • Target scenario: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Delta VDB200?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta VDB200.

Which bathroom layouts should pick a larger blower than Delta VDB200?

Do not force Delta VDB200 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Delta VDB200 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Delta VDB200 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will Delta VDB200 disturb adjacent bedrooms during night use?

Acoustic measurement places Delta VDB200 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Delta VDB200 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Delta VDB200 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Delta VDB200 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta VDB200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta VDB200?

Delta VDB200 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta VDB200's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta VDB200's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Delta VDB200 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta VDB200 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories