Skip to main content
Grant Estimator

Delta VDBFRS200HT Exhaust Fan Specifications

ENERGY STAR PD #3417554 · In-line (single-port) · Qualified 2024-01-19
Verified Specification Summary

Certified by EPA ENERGY STAR, Delta VDBFRS200HT delivers 200 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 200 sq ft (8-ft height) or 177 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta VDBFRS200HT Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
200 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.9 CFM/W (#519/1,145)
Static Retention
0.1" test only
Motor Draw
40.8 W (14.9 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta VDBFRS200HT vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta VDBFRS200HT (EPA filing PD #3417554) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 200 CFM (#45 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Delta VDBFRS200HT (series: BreezFresh) under PD #3417554 (121 models registered, 2024-01-19). Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 40.8 watts, about 14.9 kWh/yr (~$2.38/yr at $0.16/kWh) for 1 hr/day shower timers or 357.4 kWh/yr (~$57.18/yr) continuously. Closest competing matches include Fantech FreshFlow(579865) (200.0 CFM) and Broan L200EL (200.0 CFM).

Why does rigid 6 in. diameter ducting protect Delta VDBFRS200HT airflow?

Connecting Delta VDBFRS200HT through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Delta VDBFRS200HT performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta VDBFRS200HT lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series VDBFRS200HT / BreezFresh PD ID 3417554 (Qualified 2024-01-19)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (200 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Delta VDBFRS200HT?

Calculated coverage metrics translate Delta VDBFRS200HT airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta VDBFRS200HT
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 200 sq ft1 CFM/sq ft @ 200 CFM
Tall Bath (9-ft Ceiling)Up to 177 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 150 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)14.9 kWh/yr (~$2.38/yr)40.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2357.4 kWh/yr (~$57.18/yr)40.8 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Delta VDBFRS200HT?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Fantech FreshFlow(579865) 200 / N/A CFM Unpublished 5.4 CFM/W 6 in. diameter
Broan L200EL 200 / N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Broan L150E 210 / 175.2 CFM Unpublished 5.0 CFM/W 8 in. diameter
Zephyr ZSI-E30BS-ES 200 / N/A CFM Unpublished 3.5 CFM/W 8 in. diameter
Zephyr ZSI-E36BS-ES 200 / N/A CFM Unpublished 3.5 CFM/W 8 in. diameter

Does Delta VDBFRS200HT match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta VDBFRS200HT percentage capacity without sending data.

Where should contractors skip Delta VDBFRS200HT on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta VDBFRS200HT carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 150 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 200 CFM net static output
  • Works well for: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Delta VDBFRS200HT?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta VDBFRS200HT.

Will long attic ducting choke Delta VDBFRS200HT capacity?

Because static drag at 0.25 in. w.g. lowers Delta VDBFRS200HT from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Delta VDBFRS200HT compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Delta VDBFRS200HT produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Delta VDBFRS200HT consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Delta VDBFRS200HT draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Delta VDBFRS200HT pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta VDBFRS200HT's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta VDBFRS200HT?

Delta VDBFRS200HT features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta VDBFRS200HT's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta VDBFRS200HT's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Delta VDBFRS200HT score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta VDBFRS200HT delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Delta VDBFRS200HT?

Rule out Delta VDBFRS200HT when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories