Greenheck CSP-A200 Exhaust Fan Specifications

ENERGY STAR PD #2354803 · In-line (single-port) · Qualified 2020-02-14
Verified Specification Summary

Certified by EPA ENERGY STAR, Greenheck CSP-A200 delivers 213 CFM free-air (204 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 204 sq ft (8-ft height) or 181 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck CSP-A200 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
213 / 204 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
95.8% @ 0.25"
Motor Draw
54.6 W (19.9 kWh/yr)
Duct & Tier
8 x 6 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck CSP-A200 vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck CSP-A200 (EPA filing PD #2354803) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 204 CFM out of 213 CFM (95.8% retention, 8.1 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places CSP-A200 (series: CSP) (PD #2354803) among 31 Greenheck entries qualified through 2020-02-14. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 54.6 watts, about 19.9 kWh/yr (~$3.18/yr at $0.16/kWh) for 1 hr/day shower timers or 478.3 kWh/yr (~$76.53/yr) continuously. Closest competing matches include Dayton 6WZN6 (213.0 CFM) and Broan L150E (210.0 CFM).

Why does rigid 8 x 6 in. rectangular ducting protect Greenheck CSP-A200 airflow?

Connecting Greenheck CSP-A200 through rigid 8 x 6 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Greenheck CSP-A200 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Greenheck CSP-A200 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series CSP-A200 / CSP PD ID 2354803 (Qualified 2020-02-14)
Duct Connection 8 x 6 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (204 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Greenheck CSP-A200?

Calculated coverage metrics translate Greenheck CSP-A200 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Greenheck CSP-A200
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 204 sq ft1 CFM/sq ft @ 204 CFM
Tall Bath (9-ft Ceiling)Up to 181 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 154 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)19.9 kWh/yr (~$3.18/yr)54.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2478.3 kWh/yr (~$76.53/yr)54.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Greenheck CSP-A200?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 6WZN6 213 / 204 CFM Unpublished 3.9 CFM/W 8 x 8 in. rectangular
Broan L150E 210 / 175.2 CFM Unpublished 5.0 CFM/W 8 in. diameter
Broan L200EL 200 / N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Zephyr ZSI-E30BS-ES 200 / N/A CFM Unpublished 3.5 CFM/W 8 in. diameter
Zephyr ZSI-E36BS-ES 200 / N/A CFM Unpublished 3.5 CFM/W 8 in. diameter

Does Greenheck CSP-A200 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Greenheck CSP-A200 percentage capacity without sending data.

Where should contractors skip Greenheck CSP-A200 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Greenheck CSP-A200 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 154 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 204 CFM net static output
  • Works well for: Collar pairs with 8 x 6 in. rectangular duct straight outdoors

Which homeowner questions come up most for Greenheck CSP-A200?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Greenheck CSP-A200.

What duct and room conditions disqualify Greenheck CSP-A200?

Rule out Greenheck CSP-A200 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Greenheck CSP-A200 capacity?

Because static drag at 0.25 in. w.g. lowers Greenheck CSP-A200 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 8 x 6 in. rectangular rigid ducting straight to a dedicated exterior damper.

How loud is Greenheck CSP-A200 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Greenheck CSP-A200 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Greenheck CSP-A200 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Greenheck CSP-A200 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Greenheck CSP-A200 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck CSP-A200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck CSP-A200?

Greenheck CSP-A200 features a 8 x 6 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck CSP-A200's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck CSP-A200's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Greenheck CSP-A200 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Greenheck CSP-A200 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories