Skip to main content
Grant Estimator

Dayton 6WZN6 Exhaust Fan Specifications

ENERGY STAR PD #2366108 · In-line (single-port) · Qualified 2020-02-14
Verified Specification Summary

The Dayton 6WZN6 (6WZN6) moves 213 CFM at 0.1 in. w.g. (204 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 3.9 CFM/W efficacy, sizing bathrooms up to 204 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 6WZN6 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
213 / 204 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
95.8% @ 0.25"
Motor Draw
54.6 W (19.9 kWh/yr)
Duct & Tier
8 x 8 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Dayton 6WZN6 vs. 1,145-Model ENERGY STAR Benchmarks show?

Dayton 6WZN6 (EPA filing PD #2366108) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 204 CFM out of 213 CFM (95.8% retention, 8.1 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 8 x 8 in. rectangular housing before entering attic bays.

Certification audit confirms Dayton 6WZN6 (series: 6WZN6) under PD #2366108 (12 models registered, 2020-02-14). Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 54.6 watts, about 19.9 kWh/yr (~$3.18/yr at $0.16/kWh) for 1 hr/day shower timers or 478.3 kWh/yr (~$76.53/yr) continuously. Closest competing matches include Greenheck CSP-A200 (213.0 CFM) and Broan L150E (210.0 CFM).

How does duct geometry alter Dayton 6WZN6 static pressure?

Smooth 8 x 8 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Dayton 6WZN6?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Dayton 6WZN6 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Dayton (12 models) ENERGY STAR Certified Partner
Model Number & Series 6WZN6 / 6WZN6 PD ID 2366108 (Qualified 2020-02-14)
Duct Connection 8 x 8 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (204 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Dayton 6WZN6 ventilate safely?

Sizing outputs below convert Dayton 6WZN6 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Dayton 6WZN6
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 204 sq ft1 CFM/sq ft @ 204 CFM
Tall Bath (9-ft Ceiling)Up to 181 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 154 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)19.9 kWh/yr (~$3.18/yr)54.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2478.3 kWh/yr (~$76.53/yr)54.6 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Dayton 6WZN6 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Greenheck CSP-A200 213 / 204 CFM Unpublished 3.9 CFM/W 8 x 6 in. rectangular
Broan L150E 210 / 175.2 CFM Unpublished 5.0 CFM/W 8 in. diameter
Broan L200EL 200 / N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Zephyr ZSI-E30BS-ES 200 / N/A CFM Unpublished 3.5 CFM/W 8 in. diameter
Zephyr ZSI-E36BS-ES 200 / N/A CFM Unpublished 3.5 CFM/W 8 in. diameter

Will Dayton 6WZN6 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Dayton 6WZN6 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Who should not install Dayton 6WZN6 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Dayton 6WZN6 for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 154 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 204 sq ft with 8-ft ceilings (181 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 8 x 8 in. rectangular

What key rules and numbers govern Dayton 6WZN6?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Dayton 6WZN6.

How does Dayton 6WZN6 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Dayton 6WZN6 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Dayton 6WZN6?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Dayton 6WZN6 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 6WZN6's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Dayton 6WZN6?

Dayton 6WZN6 features a 8 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Dayton 6WZN6's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 6WZN6's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Dayton 6WZN6 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Dayton 6WZN6 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Dayton 6WZN6 undersized or poorly matched for a bath renovation?

Skip Dayton 6WZN6 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Dayton 6WZN6 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Dayton 6WZN6 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 8 x 8 in. rectangular duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories