The Delta 80F-DGL (BreezGreenBuilder) moves 80 CFM at 0.1 in. w.g. (68.8 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones), and delivers 9.5 CFM/W efficacy, sizing bathrooms up to 68 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 80F-DGL Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 68.8 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 9.5 CFM/W (#234/1,145)
- Static Retention
- 86.0% @ 0.25"
- Motor Draw
- 8.4 W (3.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta 80F-DGL vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.8 CFM out of 80 CFM (86.0% retention, 1.7 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places 80F-DGL (series: BreezGreenBuilder) (PD #2343296) among 121 Delta entries qualified through 2018-08-24. Lighting kit: No. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.4 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 73.6 kWh/yr (~$11.78/yr) continuously. Closest competing matches include Delta 80F (80.0 CFM) and Delta GBR80 (80.0 CFM).
Where does Delta 80F-DGL sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.8 sones against all 1,145 EPA listings.
How does duct geometry alter Delta 80F-DGL static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Delta 80F-DGL?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta 80F-DGL alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 80F-DGL / BreezGreenBuilder | PD ID 2343296 (Qualified 2018-08-24) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (68.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Delta 80F-DGL ventilate safely?
Sizing outputs below convert Delta 80F-DGL tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 61 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.1 kWh/yr (~$0.50/yr) | 8.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 73.6 kWh/yr (~$11.78/yr) | 8.4 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Delta 80F-DGL closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta 80F | 80 / 68.8 CFM | 0.8 sones (Same) | 9.5 CFM/W | 4 in. diameter |
| Delta GBR80 | 80 / 68.8 CFM | 0.8 sones (Same) | 9.5 CFM/W | 4 in. diameter |
| Panasonic RG-S80LHA | 80 / 83.9 CFM | 0.5 sones (-0.30) | 9.3 CFM/W | 4 in. diameter |
| Revent RVL80 | 80 / 89 CFM | 0.8 sones (Same) | 12.0 CFM/W | 4 in. diameter |
| KORA SBF90DC-MS | 98.1 / N/A CFM | 0.7 sones (-0.10) | 10.7 CFM/W | 4 in. diameter |
Will Delta 80F-DGL clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Delta 80F-DGL satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
What plumbing or duct constraints rule out Delta 80F-DGL?
Compare where Delta 80F-DGL excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 68 sq ft with 8-ft ceilings (61 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Delta 80F-DGL?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta 80F-DGL.
How does Delta 80F-DGL handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta 80F-DGL yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Delta 80F-DGL quiet enough for a primary bedroom bathroom?
At 0.8 sones, Delta 80F-DGL operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Delta 80F-DGL energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta 80F-DGL pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 80F-DGL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta 80F-DGL?
Delta 80F-DGL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta 80F-DGL's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 80F-DGL's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Delta 80F-DGL serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta 80F-DGL supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Delta 80F-DGL for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta 80F-DGL lacks adequate reserve.