Tested under HVI protocols, the Canarm CEP80 exhaust unit achieves 80 CFM at 0.1 in. w.g. (70.9 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 70 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Canarm CEP80 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 70.9 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 88.6% @ 0.25"
- Motor Draw
- 19.0 W (6.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Canarm CEP80 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.9 CFM out of 80 CFM (88.6% retention, 0.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Canarm's 5-unit lineup, CEP80 (series: CEP) carries PD #4510682 dating to 2025-08-22. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 19.0 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 166.4 kWh/yr (~$26.62/yr) continuously. Closest competing matches include ACIQ AEP80 (80.0 CFM) and Cyclone ESCBP80 (80.0 CFM).
Where do Canarm CEP80 sones rank across EPA ENERGY STAR fans?
Comparing Canarm CEP80 (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Canarm CEP80 CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Canarm CEP80, preventing premature peeling paint and mold growth.
How does Canarm CEP80 measure up on airflow and noise ratings?
Each row below breaks down Canarm CEP80 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Canarm (5 models) | ENERGY STAR Certified Partner |
| Model Number & Series | CEP80 / CEP | PD ID 4510682 (Qualified 2025-08-22) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (70.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Canarm CEP80 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.9 kWh/yr (~$1.10/yr) | 19.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 166.4 kWh/yr (~$26.62/yr) | 19.0 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Canarm CEP80?
Compare Canarm CEP80 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Cyclone ESCBP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Revent RVPR80 | 80 / 66.2 CFM | 0.7 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Ortech ODE-8007 | 80 / 69.8 CFM | 0.7 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Air King AK80LS | 80 / 61.5 CFM | 0.7 sones (Same) | 4.5 CFM/W | 4 in. diameter |
Can you size Canarm CEP80 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Canarm CEP80 verified capacity.
Who should not install Canarm CEP80 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Canarm CEP80 for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 70.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 0.7 sones up to 70 sq ft
- Primary match: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Canarm CEP80?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Canarm CEP80.
What electrical efficiency and runtime kWh define Canarm CEP80?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Canarm CEP80 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Canarm CEP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Canarm CEP80?
Canarm CEP80 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Canarm CEP80's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Canarm CEP80's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Canarm CEP80 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Canarm CEP80 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Canarm CEP80 undersized or poorly matched for a bath renovation?
Skip Canarm CEP80 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Canarm CEP80 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Canarm CEP80 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does Canarm CEP80 sound output compare to noisy contractor-grade fans?
Rated at 0.7 sones, Canarm CEP80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)