Tested under HVI protocols, the Broan-Nutone BEL6 exhaust unit achieves 60 CFM at 0.1 in. w.g. (52.6 CFM at 0.25 in. w.g.), registers #239 of 607 in quietness (0.9 sones) and delivers 3.6 CFM/W efficacy, covering standard baths up to 52 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone BEL6 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 60 / 52.6 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 87.7% @ 0.25"
- Motor Draw
- 16.7 W (6.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone BEL6 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 52.6 CFM out of 60 CFM (87.7% retention, equal to the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3626866 verifies BEL6 (series: ROOMSIDE) under Broan-Nutone (48 listed models, qualified 2024-06-21). Lighting kit: Yes. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Commercial Electric BPT13-12EN (50.0 CFM) and MaxLite EBF17-50-1-W (50.0 CFM).
Where do Broan-Nutone BEL6 sones rank across EPA ENERGY STAR fans?
Comparing Broan-Nutone BEL6 (0.9 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Broan-Nutone BEL6 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan-Nutone BEL6, preventing premature peeling paint and mold growth.
How does Broan-Nutone BEL6 measure up on airflow and noise ratings?
Each row below breaks down Broan-Nutone BEL6 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BEL6 / ROOMSIDE | PD ID 3626866 (Qualified 2024-06-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (52.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Broan-Nutone BEL6 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 52 sq ft | 1 CFM/sq ft @ 52.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 46 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan-Nutone BEL6?
Compare Broan-Nutone BEL6 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Commercial Electric BPT13-12EN | 50 / 49.3 CFM | 1.0 sones (+0.10) | 3.7 CFM/W | 3 in. diameter |
| MaxLite EBF17-50-1-W | 50 / 49.3 CFM | 1.0 sones (+0.10) | 3.7 CFM/W | 3 in. diameter |
| HomeWerks Worldwide 7105-10 | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7105-10-MB | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| Nektra 33003851 | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
Can you size Broan-Nutone BEL6 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan-Nutone BEL6 verified capacity.
Which bath layouts should avoid specifying Broan-Nutone BEL6?
Match Broan-Nutone BEL6 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 52.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.9 sones up to 52 sq ft
- Optimal use: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Broan-Nutone BEL6?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan-Nutone BEL6.
What does Broan-Nutone BEL6 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan-Nutone BEL6 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan-Nutone BEL6 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone BEL6's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone BEL6?
Broan-Nutone BEL6 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone BEL6's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone BEL6's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Broan-Nutone BEL6 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone BEL6 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Broan-Nutone BEL6 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan-Nutone BEL6.
What happens to Broan-Nutone BEL6 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan-Nutone BEL6 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Broan-Nutone BEL6 sit on acoustic comfort for senior homeowners?
Measuring 0.9 sones, Broan-Nutone BEL6 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)