The Tech Drive TD-BF-23L-5CCT(BL) (TD) moves 130 CFM at 0.1 in. w.g. (116.4 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones), and delivers 4.6 CFM/W efficacy, sizing bathrooms up to 116 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-23L-5CCT(BL) Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 116.4 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 89.5% @ 0.25"
- Motor Draw
- 28.3 W (10.3 kWh/yr)
- Duct & Tier
- 5 in. diameter · Standard

What does Tech Drive TD-BF-23L-5CCT(BL) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 116.4 CFM out of 130 CFM (89.5% retention, 1.8 pts higher retention than the 87.7% median). Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places TD-BF-23L-5CCT(BL) (series: TD) (PD #4697614) among 27 Tech Drive entries qualified through 2026-09-02. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.3 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.9 kWh/yr (~$39.66/yr) continuously. Closest competing matches include Loren Cook Company GC-222 (115.0 CFM) and Ortech ODC-1109 (116.0 CFM).
Where does Tech Drive TD-BF-23L-5CCT(BL) sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.2 sones against all 1,145 EPA listings.
How does duct geometry alter Tech Drive TD-BF-23L-5CCT(BL) static pressure?
Smooth 5 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Tech Drive TD-BF-23L-5CCT(BL)?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Tech Drive TD-BF-23L-5CCT(BL) alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-BF-23L-5CCT(BL) / TD | PD ID 4697614 (Qualified 2026-09-02) |
| Duct Connection | 5 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (116.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Tech Drive TD-BF-23L-5CCT(BL) ventilate safely?
Sizing outputs below convert Tech Drive TD-BF-23L-5CCT(BL) tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 116 sq ft | 1 CFM/sq ft @ 116.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 103 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 66 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.9 kWh/yr (~$39.66/yr) | 28.3 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Tech Drive TD-BF-23L-5CCT(BL) closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Loren Cook Company GC-222 | 115 / 85 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4.5 x 6 in. rectangular |
| Ortech ODC-1109 | 116 / 106.8 CFM | 1.1 sones (-0.10) | 4.7 CFM/W | 4 in. diameter |
| Hampton Bay 7136-02 | 140 / 124.4 CFM | 1.0 sones (-0.20) | 3.9 CFM/W | 6 in. diameter |
| HomeWerks Worldwide 7136-02HW | 140 / 124.4 CFM | 1.0 sones (-0.20) | 3.9 CFM/W | 6 in. diameter |
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones (+0.30) | 4.7 CFM/W | 6 in. diameter |
Will Tech Drive TD-BF-23L-5CCT(BL) clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Tech Drive TD-BF-23L-5CCT(BL) satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does Tech Drive TD-BF-23L-5CCT(BL) fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Tech Drive TD-BF-23L-5CCT(BL).
Limitations & Who Should Skip
- Steam or walk-in tub room > 66 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 116 sq ft with 8-ft ceilings (103 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 5 in. diameter
What key rules and numbers govern Tech Drive TD-BF-23L-5CCT(BL)?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Tech Drive TD-BF-23L-5CCT(BL).
Is Tech Drive TD-BF-23L-5CCT(BL) code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-23L-5CCT(BL) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Tech Drive TD-BF-23L-5CCT(BL)?
Do not force Tech Drive TD-BF-23L-5CCT(BL) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Tech Drive TD-BF-23L-5CCT(BL) retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Tech Drive TD-BF-23L-5CCT(BL) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 5 in. diameter metal duct transitions.
Will Tech Drive TD-BF-23L-5CCT(BL) disturb adjacent bedrooms during night use?
Acoustic measurement places Tech Drive TD-BF-23L-5CCT(BL) at 1.2 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Tech Drive TD-BF-23L-5CCT(BL) continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Tech Drive TD-BF-23L-5CCT(BL) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Tech Drive TD-BF-23L-5CCT(BL) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-23L-5CCT(BL)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive TD-BF-23L-5CCT(BL)?
Tech Drive TD-BF-23L-5CCT(BL) features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive TD-BF-23L-5CCT(BL)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-23L-5CCT(BL)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)