Rated for 150 CFM open-air (130.3 CFM at 0.25 in. w.g.), ACIQ AEPD150SC registers #239 of 607 in quietness (0.9 sones) and delivers 11.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 130 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AEPD150SC Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 130.3 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 11.4 CFM/W (#115/1,145)
- Static Retention
- 86.9% @ 0.25"
- Motor Draw
- 13.2 W (4.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does ACIQ AEPD150SC vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 130.3 CFM out of 150 CFM (86.9% retention, 0.8 pts lower retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places AEPD150SC (series: AEPD) (PD #4005978) among 15 ACIQ entries qualified through 2025-02-21. Lighting kit: No. At 11.4 CFM/W (#115 of 1,145, top 10.7% of 1,145 rated models, more efficient than 89.3% of rated models, 6.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.2 watts, about 4.8 kWh/yr (~$0.77/yr at $0.16/kWh) for 1 hr/day shower timers or 115.6 kWh/yr (~$18.50/yr) continuously. Closest competing matches include Revent RVL150 (150.0 CFM) and Revent RVLH150 (150.0 CFM).
How does ACIQ AEPD150SC acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against ACIQ AEPD150SC (0.9 sones).
How do flex elbows choke ACIQ AEPD150SC at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps ACIQ AEPD150SC moving full rated CFM.
Does ACIQ AEPD150SC meet residential exhaust fan code specs?
Inspect ACIQ AEPD150SC mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | ACIQ (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AEPD150SC / AEPD | PD ID 4005978 (Qualified 2025-02-21) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (130.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match ACIQ AEPD150SC airflow output?
Annual electricity figures and room square-footage ceilings below reflect ACIQ AEPD150SC tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 130 sq ft | 1 CFM/sq ft @ 130.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 115 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 80 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.8 kWh/yr (~$0.77/yr) | 13.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 115.6 kWh/yr (~$18.50/yr) | 13.2 W x 8,760 hrs / 1,000 |
Which competing models share ACIQ AEPD150SC airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVL150 | 150 / 152.1 CFM | 0.8 sones (-0.10) | 12.1 CFM/W | 6 in. diameter |
| Revent RVLH150 | 150 / 152.1 CFM | 0.8 sones (-0.10) | 12.1 CFM/W | 6 in. diameter |
| Revent RVS150 | 150 / 155.8 CFM | 0.7 sones (-0.20) | 12.0 CFM/W | 6 in. diameter |
| Revent RVSH150 | 150 / 155.8 CFM | 0.7 sones (-0.20) | 12.0 CFM/W | 6 in. diameter |
| Utilitech 7116-02 | 150 / 123.8 CFM | 1.0 sones (+0.10) | 8.1 CFM/W | 6 in. diameter |
How much airflow margin does ACIQ AEPD150SC give your bath?
Run a quick local room-volume check for ACIQ AEPD150SC by entering square footage and ceiling height to spot under-vented steam risks early.
What plumbing or duct constraints rule out ACIQ AEPD150SC?
Compare where ACIQ AEPD150SC excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 80 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 130 sq ft with 8-ft ceilings (115 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about ACIQ AEPD150SC?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to ACIQ AEPD150SC.
Why might a contractor swap ACIQ AEPD150SC for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, ACIQ AEPD150SC lacks adequate reserve.
How does ACIQ AEPD150SC handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., ACIQ AEPD150SC yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is ACIQ AEPD150SC quiet enough for a primary bedroom bathroom?
At 0.9 sones, ACIQ AEPD150SC operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is ACIQ AEPD150SC energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can ACIQ AEPD150SC pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AEPD150SC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing ACIQ AEPD150SC?
ACIQ AEPD150SC features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change ACIQ AEPD150SC's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AEPD150SC's safe coverage footprint from 50 sq ft to 44 sq ft.
Can ACIQ AEPD150SC serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: ACIQ AEPD150SC supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)